» Articles » PMID: 36305761

Biomechanical Analysis of Posterior Open-Wedge Osteotomy and Glenoid Concavity Reconstruction Using an Implant-Free, J-Shaped Iliac Crest Bone Graft

Overview
Journal Am J Sports Med
Publisher Sage Publications
Specialty Orthopedics
Date 2022 Oct 28
PMID 36305761
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Posterior open-wedge osteotomy and glenoid reconstruction using a J-shaped iliac crest bone graft showed promising clinical results for the treatment of posterior instability with excessive glenoid retroversion and posteroinferior glenoid deficiency.

Purpose: To evaluate the biomechanical performance of the posterior J-shaped graft to restore glenoid retroversion and posteroinferior deficiency in a cadaveric shoulder instability model.

Study Design: Controlled laboratory study.

Methods: A posterior glenoid open-wedge osteotomy was performed in 6 fresh-frozen shoulders, allowing the glenoid retroversion to be set at 0°, 10°, and 20°. At each of these 3 preset angles of glenoid retroversion, the following conditions were simulated: (1) intact joint, (2) posterior Bankart lesion, (3) 20% posteroinferior glenoid deficiency, and (4) posterior J-shaped graft (at 0° of retroversion). With the humerus in the Jerk position (60° of glenohumeral anteflexion, 60° of internal rotation), stability was evaluated by measuring posterior humeral head (HH) translation (in mm) and peak translational force (in N) to translate the HH over 25% of the glenoid width. Glenohumeral contact patterns were measured using pressure-sensitive sensors. Fixation of the posterior J-graft was analyzed by recording graft micromovements during 3000 cycles of 5-mm anteroposterior HH translations.

Results: Reconstructing the glenoid with a posterior J-graft to 0° of retroversion significantly increased stability compared with a posterior Bankart lesion and posteroinferior glenoid deficiency in all 3 preset degrees of retroversion ( < .05). There was no significant difference in joint stability comparing the posterior J-graft with an intact joint at 0° of retroversion. The posterior J-graft restored mean contact area and contact pressure comparable with that of the intact condition with 0° of retroversion (222 vs 223 mm, = .980; and 0.450 vs 0.550 MPa, = .203). The mean total graft displacement after 3000 cycles of loading was 43 ± 84 µm, and the mean maximal mediolateral graft bending was 508 ± 488 µm.

Conclusion: Biomechanical analysis of the posterior J-graft demonstrated reliable restoration of initial glenohumeral joint stability, normalization of contact patterns comparable with that of an intact shoulder joint with neutral retroversion, and secure initial graft fixation in the cadaveric model.

Clinical Relevance: This study confirms that the posterior J-graft can restore stability and glenohumeral loading conditions comparable with those of an intact shoulder.

Citing Articles

Arthroscopic Posterior Glenoid Osteotomy.

Hachem A, Pereira J, Rius X, Campagnoli A Arthrosc Tech. 2024; 13(1):102827.

PMID: 38312878 PMC: 10837975. DOI: 10.1016/j.eats.2023.09.003.


Anterolateral Acromioplasty Reduces Gliding Resistance Between the Supraspinatus Tendon and the Coracoacromial Arch in a Cadaveric Model.

Ernstbrunner L, Werthel J, Gotschi T, Hooke A, Zhao C Arthrosc Sports Med Rehabil. 2024; 6(1):100845.

PMID: 38226343 PMC: 10788404. DOI: 10.1016/j.asmr.2023.100845.

References
1.
Itoi E, Lee S, Berglund L, Berge L, An K . The effect of a glenoid defect on anteroinferior stability of the shoulder after Bankart repair: a cadaveric study. J Bone Joint Surg Am. 2000; 82(1):35-46. DOI: 10.2106/00004623-200001000-00005. View

2.
Ortmaier R, Moroder P, Hirzinger C, Resch H . Posterior open wedge osteotomy of the scapula neck for the treatment of advanced shoulder osteoarthritis with posterior head migration in young patients. J Shoulder Elbow Surg. 2017; 26(7):1278-1286. DOI: 10.1016/j.jse.2016.11.005. View

3.
Pauzenberger L, Dyrna F, Obopilwe E, Heuberer P, Arciero R, Anderl W . Biomechanical Evaluation of Glenoid Reconstruction With an Implant-Free J-Bone Graft for Anterior Glenoid Bone Loss. Am J Sports Med. 2017; 45(12):2849-2857. DOI: 10.1177/0363546517716927. View

4.
Walch G, Ascani C, Boulahia A, Nove-Josserand L, Edwards T . Static posterior subluxation of the humeral head: an unrecognized entity responsible for glenohumeral osteoarthritis in the young adult. J Shoulder Elbow Surg. 2002; 11(4):309-14. DOI: 10.1067/mse.2002.124547. View

5.
SCOTT Jr D . Treatment of recurrent posterior dislocations of the shoulder by glenoplasty. Report of three cases. J Bone Joint Surg Am. 1967; 49(3):471-6. View