» Articles » PMID: 36299642

High-speed Wide-field Photoacoustic Microscopy Using a Cylindrically Focused Transparent High-frequency Ultrasound Transducer

Overview
Journal Photoacoustics
Date 2022 Oct 27
PMID 36299642
Authors
Affiliations
Soon will be listed here.
Abstract

Combining focused optical excitation and high-frequency ultrasound detection, optical-resolution photoacoustic microscopy (OR-PAM) can provide micrometer-level spatial resolution with millimeter-level penetration depth and has been employed in a variety of biomedical applications. However, it remains a challenge for OR-PAM to achieve a high imaging speed and a large field of view at the same time. In this work, we report a new approach to implement high-speed wide-field OR-PAM, using a cylindrically-focused transparent ultrasound transducer (CFT-UT). The CFT-UT is made of transparent lithium niobate coated with indium-tin-oxide as electrodes. A transparent cylindrical lens is attached to the transducer surface to provide an acoustic focal line with a length of 9 mm. The excitation light can pass directly through the CFT-UT from the above and thus enables a reflection imaging mode. High-speed imaging is achieved by fast optical scanning of the focused excitation light along the CFT-UT focal line. With the confocal alignment of the optical excitation and acoustic detection, a relatively high detection sensitivity is maintained over the entire scanning range. The CFT-UT-based OR-PAM system has achieved a cross-sectional frame rate of 500 Hz over the scanning range of 9 mm. We have characterized the system's performance on phantoms and demonstrated its application on small animal models in vivo. We expect the new CFT-UT-based OR-PAM will find matched biomedical applications that need high imaging speed over a large field of view.

Citing Articles

Transparent ultrasonic transducers based on relaxor ferroelectric crystals for advanced photoacoustic imaging.

Qiu C, Zhang Z, Xu Z, Qiao L, Ning L, Zhang S Nat Commun. 2024; 15(1):10580.

PMID: 39632872 PMC: 11618688. DOI: 10.1038/s41467-024-55032-0.


High speed innovations in photoacoustic microscopy.

Zhu X, Menozzi L, Cho S, Yao J Npj Imaging. 2024; 2(1):46.

PMID: 39525278 PMC: 11541221. DOI: 10.1038/s44303-024-00052-0.


Investigation of an Active Focusing Planar Piezoelectric Ultrasonic Transducer.

Wu Q, You B, Zhang X, Tu J Sensors (Basel). 2024; 24(13).

PMID: 39000861 PMC: 11244312. DOI: 10.3390/s24134082.


Tailored photoacoustic apertures with superimposed optical holograms.

Howe G, Tang M, Rowlands C Biomed Opt Express. 2024; 14(12):6361-6380.

PMID: 38420325 PMC: 10898579. DOI: 10.1364/BOE.507453.


An ultrasensitive and broadband transparent ultrasound transducer for ultrasound and photoacoustic imaging in-vivo.

Cho S, Kim M, Ahn J, Kim Y, Lim J, Park J Nat Commun. 2024; 15(1):1444.

PMID: 38365897 PMC: 10873420. DOI: 10.1038/s41467-024-45273-4.


References
1.
Hu S, Maslov K, Wang L . Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed. Opt Lett. 2011; 36(7):1134-6. PMC: 3076123. DOI: 10.1364/OL.36.001134. View

2.
Xi L, Sun J, Zhu Y, Wu L, Xie H, Jiang H . Photoacoustic imaging based on MEMS mirror scanning. Biomed Opt Express. 2011; 1(5):1278-1283. PMC: 3018125. DOI: 10.1364/BOE.1.001278. View

3.
Shoroghi M, Sadrolsadat S, Razzaghi M, Farahbakhsh F, Sheikhvatan M, Sheikhfathollahi M . Effect of different epinephrine concentrations on local bleeding and hemodynamics during dermatologic surgery. Acta Dermatovenerol Croat. 2008; 16(4):209-14. View

4.
Park K, Kim J, Lee C, Jeon S, Lim G, Kim C . Handheld Photoacoustic Microscopy Probe. Sci Rep. 2017; 7(1):13359. PMC: 5645466. DOI: 10.1038/s41598-017-13224-3. View

5.
Zhang X, Koppal S, Zhang R, Zhou L, Butler E, Xie H . Wide-angle structured light with a scanning MEMS mirror in liquid. Opt Express. 2016; 24(4):3479-87. DOI: 10.1364/OE.24.003479. View