Generation of Dynamic Concentration Profile Using A Microfluidic Device Integrating Pneumatic Microvalves
Overview
Affiliations
Generating and maintaining the concentration dilutions of diffusible molecules in microchannels is critical for high-throughput chemical and biological analysis. Conventional serial network microfluidic technologies can generate high orders of arbitrary concentrations by a predefined microchannel network. However, a previous design requires a large occupancy area and is unable to dynamically generate different profiles in the same chip, limiting its applications. This study developed a microfluidic device enabling dynamic variations of both the concentration in the same channel and the concentration distribution in multiple channels by adjusting the flow resistance using programmable pneumatic microvalves. The key component (the pneumatic microvalve) allowed dynamic adjustment of the concentration profile but occupied a tiny space. Additionally, a Matlab program was developed to calculate the flow rates and flow resistance of various sections of the device, which provided theoretical guidance for dimension design. investigations were conducted to evaluate the microvalve deformation with widths from 100 to 300 µm and membrane thicknesses of 20 and 30 µm under the activation pressures between 0 and 2000 mbar. The flow resistance of the deformed valve was studied both numerically and experimentally and an empirical model for valve flow resistance with the form of Rh=aebP was proposed. Afterward, the fluid flow in the valve region was characterized using Micro PIV to further demonstrate the adjustment mechanism of the flow resistance. Then, the herringbone structures were employed for fast mixing to allow both quick variation of concentration and minor space usage of the channel network. Finally, an empirical formula-supported computational program was developed to provide the activation pressures required for the specific concentration profile. Both linear (Ck = -0.2 + 1) and nonlinear (Ck = (110)k) concentration distribution in four channels were varied using the same device by adjusting microvalves. The device demonstrated the capability to control the concentration profile dynamically in a small space, offering superior application potentials in analytical chemistry, drug screening, and cell biology research.
Elastin-like polypeptide coacervates as reversibly triggerable compartments for synthetic cells.
Chen C, Ganar K, de Haas R, Jarnot N, Hogeveen E, de Vries R Commun Chem. 2024; 7(1):198.
PMID: 39232074 PMC: 11374812. DOI: 10.1038/s42004-024-01270-8.
Yu Z, Chen Y, Li J, Chen C, Lu H, Chen S J Nanobiotechnology. 2024; 22(1):187.
PMID: 38632623 PMC: 11022418. DOI: 10.1186/s12951-024-02334-6.
Single-cell Technology in Stem Cell Research.
Golchin A, Shams F, Moradi F, Sadrabadi A, Parviz S, Alipour S Curr Stem Cell Res Ther. 2024; 20(1):9-32.
PMID: 38243989 DOI: 10.2174/011574888X265479231127065541.
Microfluidics for Biomedical Applications.
Xiang N, Ni Z Biosensors (Basel). 2023; 13(2).
PMID: 36831927 PMC: 9953641. DOI: 10.3390/bios13020161.