» Articles » PMID: 36263944

Composition, Emissions, and Air Quality Impacts of Hazardous Air Pollutants in Unburned Natural Gas from Residential Stoves in California

Overview
Date 2022 Oct 20
PMID 36263944
Authors
Affiliations
Soon will be listed here.
Abstract

The presence of hazardous air pollutants (HAPs) entrained in end-use natural gas (NG) is an understudied source of human health risks. We performed trace gas analyses on 185 unburned NG samples collected from 159 unique residential NG stoves across seven geographic regions in California. Our analyses commonly detected 12 HAPs with significant variability across region and gas utility. Mean regional benzene, toluene, ethylbenzene, and total xylenes (BTEX) concentrations in end-use NG ranged from 1.6-25 ppmv─benzene alone was detected in 99% of samples, and mean concentrations ranged from 0.7-12 ppmv (max: 66 ppmv). By applying previously reported NG and methane emission rates throughout California's transmission, storage, and distribution systems, we estimated statewide benzene emissions of 4,200 (95% CI: 1,800-9,700) kg yr that are currently not included in any statewide inventories─equal to the annual benzene emissions from nearly 60,000 light-duty gasoline vehicles. Additionally, we found that NG leakage from stoves and ovens while not in use can result in indoor benzene concentrations that can exceed the California Office of Environmental Health Hazard Assessment 8-h Reference Exposure Level of 0.94 ppbv─benzene concentrations comparable to environmental tobacco smoke. This study supports the need to further improve our understanding of leaked downstream NG as a source of health risk.

Citing Articles

Pulmonary vascular disease, environmental pollution, and climate change.

Lichtblau M, Reimann L, Piccari L Pulm Circ. 2024; 14(2):e12394.

PMID: 38933180 PMC: 11205889. DOI: 10.1002/pul2.12394.


Nitrogen dioxide exposure, health outcomes, and associated demographic disparities due to gas and propane combustion by U.S. stoves.

Kashtan Y, Nicholson M, Finnegan C, Ouyang Z, Garg A, Lebel E Sci Adv. 2024; 10(18):eadm8680.

PMID: 38701214 PMC: 11068006. DOI: 10.1126/sciadv.adm8680.


Climate and health benefits of a transition from gas to electric cooking.

Gould C, Bejarano M, de la Cuesta B, Jack D, Schlesinger S, Valarezo A Proc Natl Acad Sci U S A. 2023; 120(34):e2301061120.

PMID: 37582122 PMC: 10450649. DOI: 10.1073/pnas.2301061120.


Indoor wood-burning from stoves and fireplaces and incident lung cancer among Sister Study participants.

Mehta S, Elizabeth Hodgson M, Lunn R, Ashley C, Arroyave W, Sandler D Environ Int. 2023; 178:108128.

PMID: 37542784 PMC: 10530432. DOI: 10.1016/j.envint.2023.108128.


Gas and Propane Combustion from Stoves Emits Benzene and Increases Indoor Air Pollution.

Kashtan Y, Nicholson M, Finnegan C, Ouyang Z, Lebel E, Michanowicz D Environ Sci Technol. 2023; 57(26):9653-9663.

PMID: 37319002 PMC: 10324305. DOI: 10.1021/acs.est.2c09289.

References
1.
. Chemical agents and related occupations. IARC Monogr Eval Carcinog Risks Hum. 2012; 100(Pt F):9-562. PMC: 4781612. View

2.
Dols W, Emmerich S, Polidoro B . Using Coupled Energy, Airflow and IAQ Software (TRNSYS/CONTAM) to Evaluate Building Ventilation Strategies. Build Serv Eng Res Technol. 2016; 37(2):163-175. PMC: 4832575. DOI: 10.1177/0143624415619464. View

3.
Jimenez J, Canagaratna M, Donahue N, Prevot A, Zhang Q, Kroll J . Evolution of organic aerosols in the atmosphere. Science. 2009; 326(5959):1525-9. DOI: 10.1126/science.1180353. View

4.
Nazaroff W, Singer B . Inhalation of hazardous air pollutants from environmental tobacco smoke in US residences. J Expo Anal Environ Epidemiol. 2004; 14 Suppl 1:S71-7. DOI: 10.1038/sj.jea.7500361. View

5.
DAlton P . Psychophysical and behavioral characteristics of olfactory adaptation. Chem Senses. 2000; 25(4):487-92. DOI: 10.1093/chemse/25.4.487. View