» Articles » PMID: 36241854

A Comparison of the ClotPro System with Rotational Thromboelastometry in Cardiac Surgery: a Prospective Observational Study

Overview
Journal Sci Rep
Specialty Science
Date 2022 Oct 14
PMID 36241854
Authors
Affiliations
Soon will be listed here.
Abstract

Viscoelastic coagulation tests have been increasingly used for hemostasis management in cardiac surgery. The ClotPro system is a novel viscoelastic device based on principles of rotational thromboelastometry. We aimed to compare ClotPro with ROTEM and plasma coagulation assays in cardiopulmonary bypass (CPB) patients. Blood samples were collected from 25 CPB patients at (1) baseline, (2) start of CPB, (3) end of CPB, and (4) end of surgery. The EX-test, IN-test, HI-test, FIB-test parameters on ClotPro were compared with corresponding ROTEM assay (EXTEM, INTEM, HEPTEM, and FIBTEM). Standard plasma coagulation assays and endogenous thrombin generation (TG) were simultaneously evaluated. Pearson correlation analyses showed moderate correlations between clotting times (CTs) (r = 0.63-0.67; p < 0.001, respectively), and strong correlations with maximal clot firmness (MCF) (r = 0.93-0.98; p < 0.001, respectively) between ClotPro and ROTEM. EX-test and IN-test MCF parameters were interchangeable with acceptable percentage errors (EX-test MCF: 7.3%, IN-test MCF: 8.3%), but FIB-test MCF (27.0%) and CT results were not (EX-test CT: 44.7%, IN-test CT: 31.4%). The correlations of PT/INR or peak TG with EX-test CTs were higher than with EXTEM CTs (PT/INR: r = 0.80 and 0.41, peak TG: 0.43 and 0.18, respectively). FIB-test MCF has strong correlation with plasma fibrinogen and factor XIII level (r = 0.84 and 0.66, respectively). ROC analyses showed that ClotPro was capable of emulating well-established ROTEM thresholds (area under curves: 0.83-1.00). ClotPro demonstrated strong correlations in MCF parameters of ROTEM in CPB patients. It may be reasonable to modify ROTEM-based transfusion algorithm pertaining to MCF parameters to establish cut-off values for ClotPro device.

Citing Articles

Establishment and maturation of gut microbiota in White King pigeon squabs: role of pigeon milk.

Xu X, Wang Z, Jian Y, Zhang L, Zhou C, Liu L Front Microbiol. 2025; 15:1481529.

PMID: 39877755 PMC: 11772371. DOI: 10.3389/fmicb.2024.1481529.


The Efficacy of Andexanet Alfa for the Reversal of Factor Xa Inhibitors Is Not Influenced by Hemodilution with Different Volume Expanders.

Wienhold J, Rossaint R, Vandeput E, Grottke O J Clin Med. 2024; 13(22).

PMID: 39597850 PMC: 11594903. DOI: 10.3390/jcm13226706.


The establishment of reference intervals for the ClotPro thromboelastometry device in healthy dogs.

Day S, Nash K, Midwinter M, Purcell S, Goodwin W J Vet Emerg Crit Care (San Antonio). 2024; 34(6):560-569.

PMID: 39556112 PMC: 11650927. DOI: 10.1111/vec.13426.


New insights in cardiovascular anesthesia: a dual focus on clinical practice and research.

Tamura T, Yoshikawa Y, Ogawa S, Ida M, Hirata N J Anesth. 2024; 39(1):117-122.

PMID: 39470764 DOI: 10.1007/s00540-024-03421-6.


Pharmacokinetics and pharmacodynamics of low doses of recombinant tissue plasminogen activator to establish a model for biosimilarity comparisons.

Derhaschnig U, Buchtele N, Steiner M, Drucker C, Firbas C, Schorgenhofer C Res Pract Thromb Haemost. 2024; 8(6):102518.

PMID: 39268017 PMC: 11387684. DOI: 10.1016/j.rpth.2024.102518.


References
1.
Bolliger D, Gorlinger K, Tanaka K . Pathophysiology and treatment of coagulopathy in massive hemorrhage and hemodilution. Anesthesiology. 2010; 113(5):1205-19. DOI: 10.1097/ALN.0b013e3181f22b5a. View

2.
Gillissen A, van den Akker T, Caram-Deelder C, Henriquez D, Bloemenkamp K, Eikenboom J . Comparison of thromboelastometry by ROTEM Delta and ROTEM Sigma in women with postpartum haemorrhage. Scand J Clin Lab Invest. 2019; 79(1-2):32-38. DOI: 10.1080/00365513.2019.1571220. View

3.
Tibi P, McClure R, Huang J, Baker R, Fitzgerald D, Mazer C . STS/SCA/AmSECT/SABM Update to the Clinical Practice Guidelines on Patient Blood Management. J Cardiothorac Vasc Anesth. 2021; 35(9):2569-2591. DOI: 10.1053/j.jvca.2021.03.011. View

4.
Judd M, Strauss E, Hasan S, Abuelkasem E, Li J, Deshpande S . Clotting Time Results Are Not Interchangeable Between EXTEM and FIBTEM on Rotational Thromboelastometry. J Cardiothorac Vasc Anesth. 2020; 34(6):1467-1473. DOI: 10.1053/j.jvca.2019.12.030. View

5.
Heinz C, Miesbach W, Herrmann E, Sonntagbauer M, Raimann F, Zacharowski K . Greater Fibrinolysis Resistance but No Greater Platelet Aggregation in Critically Ill COVID-19 Patients. Anesthesiology. 2021; 134(3):457-467. PMC: 7864605. DOI: 10.1097/ALN.0000000000003685. View