» Articles » PMID: 36200053

Hemocompatibility of Micropatterned Biomaterial Surfaces is Dependent on Topographical Feature Size

Overview
Journal Front Physiol
Date 2022 Oct 6
PMID 36200053
Authors
Affiliations
Soon will be listed here.
Abstract

Small-diameter synthetic vascular grafts that have improved hemocompatibility and patency remain an unmet clinical need due to thrombosis. A surface modification that has potential to attenuate these failure mechanisms while promoting an endothelial layer is the micropatterning of luminal surfaces. Anisotropic features have been shown to downregulate smooth muscle cell proliferation, direct endothelial migration, and attenuate platelet adhesion and activation. However, the effect of micropatterning feature size and orientation relative to whole blood flow has yet to be investigated within a systematic study. In this work, hemocompatibility of micropattern grating sizes of 2, 5, and 10 µm were investigated. The thrombogenicity of the micropattern surface modifications were characterized by quantifying FXIIa activity, fibrin formation, and static platelet adhesion . Additionally, dynamic platelet attachment and end-point fibrin formation were quantified using an established, flowing whole blood non-human primate shunt model without antiplatelet or anticoagulant therapies. We observed a higher trend in platelet attachment and significantly increased fibrin formation for larger features. We then investigated the orientation of 2 µm gratings relative to whole blood flow and found no significant differences between the various orientations for platelet attachment, rate of linear platelet attachment, or end-point fibrin formation. MicroCT analysis of micropatterned grafts was utilized to quantify luminal patency. This work is a significant step in the development of novel synthetic biomaterials with improved understanding of hemocompatibility for use in cardiovascular applications.

Citing Articles

Vascular Damage and Repair - Are Small-Diameter Vascular Grafts Still the "Holy Grail" of Tissue Engineering?.

Bacakova L, Chlupac J, Filova E, Musilkova J, Tomsu J, Wu Y Physiol Res. 2024; 73(Suppl 1):S335-S363.

PMID: 38836460 PMC: 11412351. DOI: 10.33549/physiolres.935294.


Thrombogenicity of biodegradable metals.

Anderson D, Le H, Vu H, Johnson J, Aslan J, Goldman J Bioact Mater. 2024; 38:411-421.

PMID: 38774458 PMC: 11107095. DOI: 10.1016/j.bioactmat.2024.05.002.


Targeting the Contact Pathway of Coagulation for the Prevention and Management of Medical Device-Associated Thrombosis.

Goel A, Tathireddy H, Wang S, Vu H, Puy C, Hinds M Semin Thromb Hemost. 2023; 50(7):989-997.

PMID: 37044117 PMC: 11069398. DOI: 10.1055/s-0043-57011.

References
1.
Vandrangi P, Gott S, Kozaka R, Rodgers V, Rao M . Comparative endothelial cell response on topographically patterned titanium and silicon substrates with micrometer to sub-micrometer feature sizes. PLoS One. 2014; 9(10):e111465. PMC: 4214724. DOI: 10.1371/journal.pone.0111465. View

2.
Schieber R, Lasserre F, Hans M, Fernandez-Yague M, Diaz-Ricart M, Escolar G . Direct Laser Interference Patterning of CoCr Alloy Surfaces to Control Endothelial Cell and Platelet Response for Cardiovascular Applications. Adv Healthc Mater. 2017; 6(19). DOI: 10.1002/adhm.201700327. View

3.
Chernysh I, Nagaswami C, Kosolapova S, Peshkova A, Cuker A, Cines D . The distinctive structure and composition of arterial and venous thrombi and pulmonary emboli. Sci Rep. 2020; 10(1):5112. PMC: 7083848. DOI: 10.1038/s41598-020-59526-x. View

4.
Yu C, Xing M, Wang L, Guan G . Effects of aligned electrospun fibers with different diameters on hemocompatibility, cell behaviors and inflammation in vitro. Biomed Mater. 2020; 15(3):035005. DOI: 10.1088/1748-605X/ab673c. View

5.
Cutiongco M, Anderson D, Hinds M, Yim E . In vitro and ex vivo hemocompatibility of off-the-shelf modified poly(vinyl alcohol) vascular grafts. Acta Biomater. 2015; 25:97-108. PMC: 4762273. DOI: 10.1016/j.actbio.2015.07.039. View