Doppler Study of Portal Vein and Renal Venous Velocity Predict the Appropriate Fluid Response to Diuretic in ICU: a Prospective Observational Echocardiographic Evaluation
Overview
Authors
Affiliations
Background: Fluid overload and venous congestion are associated with morbi-mortality in the ICU (intensive care unit). Administration of diuretics to correct the fluid balance is common, although there is no strong relationship between the consequent fluid loss and clinical improvement. The aim of the study was to evaluate the ability of the portal pulsatility index, the renal venous impedance index, and the VEXUS score (venous ultrasound congestion score) to predict appropriate diuretic-induced fluid depletion.
Methods: The study had a prospective, observational, single-center observational design and was conducted in a university-affiliated medico-surgical ICU. Adult patients for whom the clinician decided to introduce loop diuretic treatment were included. Hemodynamic and ultrasound measurements (including the portal pulsatility index, renal venous impedance index and VEXUS score) were performed at inclusion and 2 hours after the initiation of the diuretics. The patients' characteristics were noted at inclusion, 24 h later, and at ICU discharge. The appropriate diuretic-induced fluid depletion was defined by a congestive score lower than 3 after diuretic fluid depletion. The congestive score included clinical and biological parameters of congestion.
Results: Eighty-one patients were included, and 43 (53%) patients presented with clinically significant congestion score at inclusion. Thirty-four patients (42%) had an appropriate response to diuretic-induced fluid depletion. None of the left- and right-sided echocardiographic parameters differed between the two groups. The baseline portal pulsatility index was the best predictor of appropriate response to diuretic-induced fluid depletion (AUC = 0.80, CI:0.70-0.92, p = 0.001), followed by the renal venous impedance index (AUC = 0.72, CI 0.61-0.84, p = 0.001). The baseline VEXUS score (AUC of 0.66 CI 0.53-0.79, p = 0.012) was poorly predictive of appropriate response to diuretic-induced fluid depletion.
Conclusion: The portal pulsatility index and the renal venous impedance index were predictive of the appropriate response to diuretic-induced fluid depletion in ICU patients. The portal pulsatility index should be evaluated in future randomized studies.
Melo R, Gioli-Pereira L, Melo E, Rola P Ultrasound J. 2025; 17(1):16.
PMID: 40029471 PMC: 11876505. DOI: 10.1186/s13089-025-00413-9.
Point-of-Care Ultrasonography in the Critical Care Unit: An Update.
Guevarra K, Greenstein Y Curr Cardiol Rep. 2025; 27(1):54.
PMID: 39954172 PMC: 11829842. DOI: 10.1007/s11886-024-02187-3.
Ruste M, Reskot R, Schweizer R, Mayet V, Fellahi J, Jacquet-Lagreze M Ann Intensive Care. 2024; 14(1):167.
PMID: 39485575 PMC: 11530414. DOI: 10.1186/s13613-024-01391-2.
Venous Excess Ultrasound for Fluid Assessment in Complex Cardiac Patients With Acute Kidney Injury.
Kanitkar S, Soni K, Vaishnav B Cureus. 2024; 16(8):e66003.
PMID: 39221348 PMC: 11366210. DOI: 10.7759/cureus.66003.
Sound waves and solutions: Point-of-care ultrasonography for acute kidney injury in cirrhosis.
Aguirre-Villarreal D, Leal-Villarreal M, Garcia-Juarez I, Argaiz E, Koratala A World J Crit Care Med. 2024; 13(2):91212.
PMID: 38855265 PMC: 11155499. DOI: 10.5492/wjccm.v13.i2.91212.