» Articles » PMID: 36192470

An Ultra-small Nine-color Spectrometer with a Two-layer Biparted Ten-dichroic-mirror Array and an Image Sensor

Overview
Journal Sci Rep
Specialty Science
Date 2022 Oct 3
PMID 36192470
Authors
Affiliations
Soon will be listed here.
Abstract

An ultra-small (54 × 58 × 8.5 mm) and large aperture (1 × 7 mm) nine-color spectrometer-using an array of ten dichroic mirrors "biparted" as two layers-was developed and used for snapshot spectral imaging. Incident-light flux with a cross section smaller than the aperture size is split into nine color fluxes with 20-nm-width contiguous wavelength bands and central wavelengths of 530, 550, 570, 590, 610, 630, 650, 670, and 690 nm. Images of the nine color fluxes are simultaneously and efficiently measured by an image sensor. Unlike a conventional dichroic-mirror array, the developed dichroic-mirror array has a unique biparted configuration that not only increases the number of colors that can be measured simultaneously but also improves the image resolution of each color flux. The developed nine-color spectrometer was used for four-capillary-array electrophoresis. Eight dyes concurrently migrating in each capillary were simultaneously quantified by nine-color laser-induced fluorescence detection. Since the nine-color spectrometer is not only ultra-small and inexpensive but also has high light throughput and sufficient spectral resolution for most spectral-imaging applications, it has the potential to be widely used in various fields.

References
1.
Gao L, Wang L . A review of snapshot multidimensional optical imaging: measuring photon tags in parallel. Phys Rep. 2016; 616:1-37. PMC: 4846296. DOI: 10.1016/j.physrep.2015.12.004. View

2.
Anazawa T, Yamazaki M, Yamamoto S, Inaba R . Ultra-small four-emission-point spectral-detection system using seven-dichroic-mirror array. Talanta. 2020; 222:121667. DOI: 10.1016/j.talanta.2020.121667. View

3.
Anazawa T, Matsunaga H, Yamamoto S, Inaba R . Highly sensitive mutation quantification by high-dynamic-range capillary-array electrophoresis (HiDy CE). Lab Chip. 2020; 20(6):1083-1091. DOI: 10.1039/c9lc00853e. View

4.
Li Q, Xue Y, Xiao G, Zhang J . New microscopic pushbroom hyperspectral imaging system for application in diabetic retinopathy research. J Biomed Opt. 2008; 12(6):064011. DOI: 10.1117/1.2821210. View

5.
Li Q, He X, Wang Y, Liu H, Xu D, Guo F . Review of spectral imaging technology in biomedical engineering: achievements and challenges. J Biomed Opt. 2013; 18(10):100901. DOI: 10.1117/1.JBO.18.10.100901. View