Racial Disparity in Oxygen Saturation Measurements by Pulse Oximetry: Evidence and Implications

Overview
Specialty Pulmonary Medicine
Date 2022 Sep 27
PMID 36166259
Authors
Affiliations
Soon will be listed here.
Abstract

The pulse oximeter is a ubiquitous clinical tool used to estimate blood oxygen concentrations. However, decreased accuracy of pulse oximetry in patients with dark skin tones has been demonstrated since as early as 1985. Most commonly, pulse oximeters may overestimate the true oxygen saturation in individuals with dark skin tones, leading to higher rates of occult hypoxemia (i.e., clinically unrecognized low blood oxygen saturation). Overestimation of oxygen saturation in patients with dark skin tones has serious clinical implications, as these patients may receive insufficiently rigorous medical care when pulse oximeter measurements suggest that their oxygen saturation is higher than the true value. Recent studies have linked pulse oximeter inaccuracy to worse clinical outcomes, suggesting that pulse oximeter inaccuracy contributes to known racial health disparities. The magnitude of device inaccuracy varies by pulse oximeter manufacturer, sensor type, and arterial oxygen saturation. The underlying reasons for decreased pulse oximeter accuracy for individuals with dark skin tones may be related to failure to control for increased absorption of red light by melanin during device development and insufficient inclusion of individuals with dark skin tones during device calibration. Inadequate regulatory standards for device approval may also play a role in decreased accuracy. Awareness of potential pulse oximeter limitations is an important step for providers and may encourage the consideration of additional clinical information for management decisions. Ultimately, stricter regulatory requirements for oximeter approval and increased manufacturer transparency regarding device performance are required to mitigate this racial bias.

Citing Articles

The Affordable Care Act's Call for Nondiscrimination: Addressing the Role of Pulse Oximetry in Racial Disparities.

Saft H, Bhakta N, Wong A, Crowder S, Sweet S, Gurubhagavatula I Ann Am Thorac Soc. 2024; 22(3):313-316.

PMID: 39625812 PMC: 11892666. DOI: 10.1513/AnnalsATS.202408-902PS.


Skin Phototype Classification with Machine Learning Based on Broadband Optical Measurements.

Yu X, Ong K, McGeehan M Sensors (Basel). 2024; 24(22).

PMID: 39599172 PMC: 11598237. DOI: 10.3390/s24227397.


Motion resistance in peripheral oxygen saturation monitoring using Biolight Analog SpO compared to Masimo SpO: a non-inferiority study.

Yang T, Liu Y, Cai F, Li Y, Mudabbar M BMC Anesthesiol. 2024; 24(1):430.

PMID: 39592943 PMC: 11600824. DOI: 10.1186/s12871-024-02823-z.


Racial Biases Associated With Pulse Oximetry: Longitudinal Social Network Analysis of Social Media Advocacy Impact.

Ahmed W, Hardey M, Winters B, Sarwal A J Med Internet Res. 2024; 26:e56034.

PMID: 39378433 PMC: 11496922. DOI: 10.2196/56034.


History and Social Implications of the Pulse Oximeter.

Zacharis D, Zhao D, Ganti L Cureus. 2024; 16(8):e68250.

PMID: 39350851 PMC: 11439841. DOI: 10.7759/cureus.68250.