Volumetric Assessment of Hepatic Grafts Using a Light Detection and Ranging System for 3D Scanning: Preliminary Data

Overview
Journal World J Hepatol
Specialty Gastroenterology
Date 2022 Sep 26
PMID 36158905
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Liver transplantation has evolved into a safe life-saving operation and remains the golden standard in the treatment of end stage liver disease. The main limiting factor in the application of liver transplantation is graft shortage. Many strategies have been developed in order to alleviate graft shortage, such as living donor partial liver transplantation and split liver transplantation for adult and pediatric patients. In these strategies, liver volume assessment is of paramount importance, as size mismatch can have severe consequences in the success of liver transplantation.

Aim: To evaluate the safety, feasibility, and accuracy of light detection and ranging (LIDAR) 3D photography in the prediction of whole liver graft volume and mass.

Methods: Seven liver grafts procured for orthotopic liver transplantation from brain deceased donors were prospectively measured with an LIDAR handheld camera and their mass was calculated and compared to their actual weight.

Results: The mean error of all measurements was 17.03 g (range 3.56-59.33 g). Statistical analysis of the data yielded a Pearson correlation coefficient index of 0.9968, indicating a strong correlation between the values and a Student's -test value of 0.26. Mean accuracy of the measurements was calculated at 97.88%.

Conclusion: Our preliminary data indicate that LIDAR scanning of liver grafts is a safe, cost-effective, and feasible method of determination of whole liver volume and mass. More data are needed to determine the precision and accuracy of this method.

References
1.
Lim M, Tan C, Cai J, Zheng J, Kow A . CT volumetry of the liver: where does it stand in clinical practice?. Clin Radiol. 2014; 69(9):887-95. DOI: 10.1016/j.crad.2013.12.021. View

2.
Overmoyer B, McLaren C, Brittenham G . Uniformity of liver density and nonheme (storage) iron distribution. Arch Pathol Lab Med. 1987; 111(6):549-54. View

3.
Simpson A, Geller D, Hemming A, Jarnagin W, Clements L, DAngelica M . Liver planning software accurately predicts postoperative liver volume and measures early regeneration. J Am Coll Surg. 2014; 219(2):199-207. PMC: 4128572. DOI: 10.1016/j.jamcollsurg.2014.02.027. View

4.
Zalevsky Z, Buller G, Chen T, Cohen M, Barton-Grimley R . Light detection and ranging (lidar): introduction. J Opt Soc Am A Opt Image Sci Vis. 2021; 38(11):LID1-LID2. DOI: 10.1364/JOSAA.445792. View

5.
Abdalla E, Denys A, Chevalier P, Nemr R, Vauthey J . Total and segmental liver volume variations: implications for liver surgery. Surgery. 2004; 135(4):404-10. DOI: 10.1016/j.surg.2003.08.024. View