» Articles » PMID: 36140120

Biosensing Chlorpyrifos in Environmental Water Samples by a Newly Developed Carbon Nanoparticle-Based Indirect Lateral Flow Assay

Overview
Specialty Biotechnology
Date 2022 Sep 23
PMID 36140120
Authors
Affiliations
Soon will be listed here.
Abstract

Pesticides are used in agriculture to prevent pests. Chlorpyrifos (CHLP) is an insecticide with potentially detrimental effects on humans, bees, and the aquatic environment. Its effects have led to a total ban by the European Union (EU), but outside the EU, CHLP is still produced and used. An indirect lateral flow immunoassay (LFIA) for the detection of CHLP was developed and integrated into a cassette to create a lateral flow device (LFD). Species-specific reporter antibodies were coupled to carbon nanoparticles to create a detector conjugate. Water samples were mixed with a specific CHLP monoclonal antibody and detector conjugate and applied to the LFD. Dose-response curves elicited the detection of low concentrations of CHLP (<1 µg/L). This sensitivity was recorded through a rapid handheld digital imaging device but also visually by naked eye. The CHLP LFD was applied to a range of European surface water samples, fortified with CHLP, revealing a sensitivity in these matrices of 2 µg/L, both by digital and visual analysis. To improve the simplicity of the CHLP LFIA, the assay reagents were dried in tubes, enabling to carry out the test by simply adding water samples and inserting the LFIA strips. This CHLP LFIA is thus suited for the on-site screening of surface waters.

Citing Articles

Development and validation of an indirect competitive lateral flow immunoassay for the detection of acetaminophen (paracetamol) in bovine urine.

Sasse S, Geballa-Koukoula A, Bovee T Anal Bioanal Chem. 2025; 417(6):1177-1186.

PMID: 39777530 PMC: 11802664. DOI: 10.1007/s00216-024-05721-y.


Highly sensitive SERS-based lateral flow immunoassay of fipronil using bimetallic Au@Ag@Ag nanorods.

Serebrennikova K, Komova N, Barshevskaya L, Zherdev A, Dzantiev B Mikrochim Acta. 2024; 191(12):749.

PMID: 39556219 DOI: 10.1007/s00604-024-06811-5.


Smartcard: an integrated approach for contaminant monitoring, from field to laboratory.

Geballa-Koukoula A, Willemsen L, Beij E, van Hoof R, Elferink A, Geballa-Koukoulas K Anal Bioanal Chem. 2024; 417(1):69-82.

PMID: 39528785 PMC: 11695648. DOI: 10.1007/s00216-024-05626-w.


Sensitive Colorimetric Lateral Flow Assays Enabled by Platinum-Group Metal Nanoparticles with Peroxidase-Like Activities.

Shao S, Wang X, Sorial C, Sun X, Xia X Adv Healthc Mater. 2024; :e2401677.

PMID: 39108051 PMC: 11799360. DOI: 10.1002/adhm.202401677.


Research on the Flow Characteristics and Reaction Mechanisms of Lateral Flow Immunoassay under Non-Uniform Flow.

Zhao X, Zhang Y, Niu Q, Wang L, Xing C, Wang Q Sensors (Basel). 2024; 24(6).

PMID: 38544252 PMC: 10974436. DOI: 10.3390/s24061989.


References
1.
Giesy J, Solomon K, Cutler G, Giddings J, Mackay D, Moore D . Ecological risk assessment of the uses of the organophosphorus insecticide chlorpyrifos, in the United States. Rev Environ Contam Toxicol. 2014; 231:1-11. DOI: 10.1007/978-3-319-03865-0_1. View

2.
Hites R . The Rise and Fall of Chlorpyrifos in the United States. Environ Sci Technol. 2021; 55(3):1354-1358. DOI: 10.1021/acs.est.0c06579. View

3.
Spirhanzlova P, Couderq S, Le Mevel S, Leemans M, Krief S, Mughal B . Short- and Long-Term Effects of Chlorpyrifos on Thyroid Hormone Axis and Brain Development in Xenopus laevis. Neuroendocrinology. 2022; 113(12):1298-1311. DOI: 10.1159/000525719. View

4.
Chi H, Wang C, Wang Z, Zhu H, Mesias V, Dai X . Highly reusable nanoporous silver sheet for sensitive SERS detection of pesticides. Analyst. 2020; 145(15):5158-5165. DOI: 10.1039/d0an00999g. View

5.
Posthuma-Trumpie G, Wichers J, Koets M, Berendsen L, van Amerongen A . Amorphous carbon nanoparticles: a versatile label for rapid diagnostic (immuno)assays. Anal Bioanal Chem. 2011; 402(2):593-600. PMC: 3249172. DOI: 10.1007/s00216-011-5340-5. View