» Articles » PMID: 36098832

Wearable Sensors for Prediction of Intraamniotic Infection in Women with Preterm Premature Rupture of Membranes: a Prospective Proof of Principle Study

Overview
Date 2022 Sep 13
PMID 36098832
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To evaluate the use of wearable sensors for prediction of intraamniotic infection in pregnant women with PPROM.

Materials And Methods: In a prospective proof of principle study, we included 50 patients diagnosed with PPROM at the University Hospital Zurich between November 2017 and May 2020. Patients were instructed to wear a bracelet during the night, which measures physiological parameters including wrist skin temperature, heart rate, heart rate variability, and breathing rate. A two-way repeated measures ANOVA was performed to evaluate the difference over time of both the wearable device measured parameters and standard clinical monitoring values, such as body temperature, pulse, leucocytes, and C-reactive protein, between women with and without intraamniotic infection.

Results: Altogether, 23 patients (46%) were diagnosed with intraamniotic infection. Regarding the physiological parameters measured with the bracelet, we observed a significant difference in breathing rate (19 vs 16 per min, P < .01) and heart rate (72 vs 67 beats per min, P = .03) in women with intraamniotic infection compared to those without during the 3 days prior to birth. In parallel to these changes standard clinical monitoring values were significantly different in the intraamniotic infection group compared to women without infection in the 3 days preceding birth.

Conclusion: Our results suggest that wearable sensors are a promising, noninvasive, patient friendly approach to support the early detection of intraamniotic infection in women with PPROM. However, confirmation of our findings in larger studies is required before implementing this technique in standard clinical management.

Citing Articles

Anti-infectious and anti-inflammatory effect of amniopatch in the treatment of spontaneous previable rupture of membranes.

Alfoldi M, Ferianec V Arch Gynecol Obstet. 2024; 310(1):615-626.

PMID: 38642127 PMC: 11169006. DOI: 10.1007/s00404-024-07399-0.


Maternal and neonatal outcomes following magnesium sulfate in the setting of chorioamnionitis: a meta-analysis.

Pergialiotis V, Sapantzoglou I, Rodolaki K, Varthaliti A, Theodora M, Antsaklis P Arch Gynecol Obstet. 2023; 309(3):917-927.

PMID: 37768342 PMC: 10866770. DOI: 10.1007/s00404-023-07221-3.


Changes in Heart Rate, Heart Rate Variability, Breathing Rate, and Skin Temperature throughout Pregnancy and the Impact of Emotions-A Longitudinal Evaluation Using a Sensor Bracelet.

Bossung V, Singer A, Ratz T, Rothenbuhler M, Leeners B, Kimmich N Sensors (Basel). 2023; 23(14).

PMID: 37514915 PMC: 10385491. DOI: 10.3390/s23146620.

References
1.
Goodale B, Shilaih M, Falco L, Dammeier F, Hamvas G, Leeners B . Wearable Sensors Reveal Menses-Driven Changes in Physiology and Enable Prediction of the Fertile Window: Observational Study. J Med Internet Res. 2019; 21(4):e13404. PMC: 6495289. DOI: 10.2196/13404. View

2.
Garbern S, Mbanjumucyo G, Umuhoza C, Sharma V, Mackey J, Tang O . Validation of a wearable biosensor device for vital sign monitoring in septic emergency department patients in Rwanda. Digit Health. 2019; 5:2055207619879349. PMC: 6769214. DOI: 10.1177/2055207619879349. View

3.
Weenk M, Koeneman M, van de Belt T, Engelen L, Goor H, Bredie S . Wireless and continuous monitoring of vital signs in patients at the general ward. Resuscitation. 2019; 136:47-53. DOI: 10.1016/j.resuscitation.2019.01.017. View

4.
Zhu T, Rothenbuhler M, Hamvas G, Hofmann A, Welter J, Kahr M . The Accuracy of Wrist Skin Temperature in Detecting Ovulation Compared to Basal Body Temperature: Prospective Comparative Diagnostic Accuracy Study. J Med Internet Res. 2021; 23(6):e20710. PMC: 8238491. DOI: 10.2196/20710. View

5.
Witt D, Kellogg R, Snyder M, Dunn J . Windows Into Human Health Through Wearables Data Analytics. Curr Opin Biomed Eng. 2019; 9:28-46. PMC: 6907085. DOI: 10.1016/j.cobme.2019.01.001. View