» Articles » PMID: 36088411

Polarization-probe Polarization-imaging System in Near-infrared Regime Using a Polarization Grating

Overview
Journal Sci Rep
Specialty Science
Date 2022 Sep 10
PMID 36088411
Authors
Affiliations
Soon will be listed here.
Abstract

A polarization-probe polarization-imaging (PPPI) system was developed for the near-infrared (NIR) regime. This system comprises two components operating as a polarization generator and a polarization analyzer to enable polarization image capture under polarized light illumination. The captured polarization images contain considerable object information because the illuminating polarized light beams are affected by many of the Mueller matrix elements. By assembling the polarization camera using two liquid crystal retarders and a polarization grating, the PPPI system offers the potential to measure the Stokes parameters fully with a high extinction ratio, even in the NIR region. The PPPI system's feasibility was demonstrated experimentally. Its dependence on the state of polarization (SoP) of the illuminating polarized light was discussed. The polarization image acquired by the PPPI system is strongly dependent on the illuminating light's SoP, so the appropriate SoP must be selected for each object to enhance the polarization image contrast. This PPPI system should expand the range of polarization imaging applications, including LiDAR, product inspection, and bio-imaging.

Citing Articles

Graphene-Templated Achiral Hybrid Perovskite for Circularly Polarized Light Sensing.

Volochanskyi O, Haider G, Alharbi E, Kakavelakis G, Mergl M, Thakur M ACS Appl Mater Interfaces. 2024; 16(39):52789-52798.

PMID: 39297304 PMC: 11450682. DOI: 10.1021/acsami.4c10289.

References
1.
Hu H, Zhao L, Li X, Wang H, Yang J, Li K . Polarimetric image recovery in turbid media employing circularly polarized light. Opt Express. 2018; 26(19):25047-25059. DOI: 10.1364/OE.26.025047. View

2.
Li X, Liu F, Han P, Zhang S, Shao X . Near-infrared monocular 3D computational polarization imaging of surfaces exhibiting nonuniform reflectance. Opt Express. 2021; 29(10):15616-15630. DOI: 10.1364/OE.423790. View

3.
Nishizawa N, Al-Qadi B, Kuchimaru T . Angular optimization for cancer identification with circularly polarized light. J Biophotonics. 2020; 14(3):e202000380. DOI: 10.1002/jbio.202000380. View

4.
Noda K, Yamada K, Momosaki R, Sakamoto M, Sasaki T, Kawatsuki N . White-light circular-polarization imaging using pairs of polarization gratings and wedge prisms. Appl Opt. 2020; 59(11):3383-3388. DOI: 10.1364/AO.384303. View

5.
Luo H, Oka K, Hagen N, Tkaczyk T, Dereniak E . Modeling and optimization for a prismatic snapshot imaging polarimeter. Appl Opt. 2006; 45(33):8400-9. DOI: 10.1364/ao.45.008400. View