SafetyCrown: a Patient-centered, Fully Digital Concept for Immediate Implant Restoration Following the One-abutment/one-time Concept-a Pilot Case Series of a New Treatment Concept
Overview
Authors
Affiliations
Introduction: The patient-centered SafetyCrown-workflow enables the immediate restoration of posterior missing teeth and short free-end situations following one-abutment/one-time within three visits and only one surgical approach. This prosthodontic rehabilitation aims to combine the advantages of cemented and screw-retained restorations.
Report: The concept has been performed with 4 restorations in 3 patients and followed up for up to 1 year (mean: 11.2 months) without technical and/or biological complication. Visit 1: Intraoral optical impression, CBCT, and tooth shade selection. Virtual implant planning is performed, and a surgical guide is printed. After exporting the planned implant position, a tooth-colored abutment is fabricated from zirconia with a 1-mm supragingival cementation line, adhesively bonded to a titanium base. Visit 2: Fully navigated implant placement with insertion of the definitive abutment. Subsequently, optical impressions are prepared for A: immediate restoration using a PMMA crown without functional contacts; B: definitive crown fabricated from monolithic zirconia and individualized. The localization of the screw channel is marked using stain thus permitting precise screw channel access, if necessary. Visit 3: After osseointegration of the implant, the definitive crown is adhesively cemented supragingival. In a retrospective analysis of PROMs ('How stressful was the treatment process […]?' (0 = not stressful at all, 100 = very stressful), mean VAS score for SafetyCrown of 14 (SD 11.7) and 29.8 (SD 23.1) for standard procedure were present.
Conclusion: The SafetyCrown offers a shortened, patient-oriented concept for implant-supported single-tooth reconstructions omitting second-stage surgery. Clinical performance and hypothesized prosthodontic benefits require confirmation via an RCT.
Waltenberger L, Reich S, Zwahlen M, Wolfart S Clin Implant Dent Relat Res. 2024; 26(6):1135-1148.
PMID: 39161052 PMC: 11660521. DOI: 10.1111/cid.13374.
Yorioka H, Otsu Y, Suzuki R, Matsunaga S, Nakano T, Abe S Int J Implant Dent. 2024; 10(1):24.
PMID: 38722448 PMC: 11082111. DOI: 10.1186/s40729-024-00538-x.
Neckel N, Pohl J, Preissner S, Wagendorf O, Sachse C, Vach K Int J Implant Dent. 2024; 10(1):13.
PMID: 38498247 PMC: 10948712. DOI: 10.1186/s40729-024-00529-y.
Sagheb K, Gorgen C, Doll S, Schmidtmann I, Wentaschek S Int J Implant Dent. 2023; 9(1):8.
PMID: 36947262 PMC: 10033796. DOI: 10.1186/s40729-023-00473-3.
Parvini P, Muller K, Cafferata E, Schwarz F, Obreja K Int J Implant Dent. 2022; 8(1):58.
PMID: 36434348 PMC: 9700553. DOI: 10.1186/s40729-022-00457-9.