» Articles » PMID: 36031182

IC-U-Net: A U-Net-based Denoising Autoencoder Using Mixtures of Independent Components for Automatic EEG Artifact Removal

Overview
Journal Neuroimage
Specialty Radiology
Date 2022 Aug 28
PMID 36031182
Authors
Affiliations
Soon will be listed here.
Abstract

Electroencephalography (EEG) signals are often contaminated with artifacts. It is imperative to develop a practical and reliable artifact removal method to prevent the misinterpretation of neural signals and the underperformance of brain-computer interfaces. Based on the U-Net architecture, we developed a new artifact removal model, IC-U-Net, for removing pervasive EEG artifacts and reconstructing brain signals. IC-U-Net was trained using mixtures of brain and non-brain components decomposed by independent component analysis. It uses an ensemble of loss functions to model complex signal fluctuations in EEG recordings. The effectiveness of the proposed method in recovering brain activities and removing various artifacts (e.g., eye blinks/movements, muscle activities, and line/channel noise) was demonstrated in a simulation study and four real-world EEG experiments. IC-U-Net can reconstruct a multi-channel EEG signal and is applicable to most artifact types, offering a promising end-to-end solution for automatically removing artifacts from EEG recordings. It also meets the increasing need to image natural brain dynamics in a mobile setting. The code and pre-trained IC-U-Net model are available at https://github.com/roseDwayane/AIEEG.

Citing Articles

Brain computer interfaces for cognitive enhancement in older people - challenges and applications: a systematic review.

Tsai P, Akpan A, Tang K, Lakany H BMC Geriatr. 2025; 25(1):36.

PMID: 39819299 PMC: 11737249. DOI: 10.1186/s12877-025-05676-4.


Parkinson's disease detection from EEG signal employing autoencoder and RBFNN-based hybrid deep learning framework utilizing power spectral density.

Jibon F, Tasbir A, Talukder M, Uddin M, Rabbi F, Uddin M Digit Health. 2024; 10:20552076241297355.

PMID: 39539721 PMC: 11558743. DOI: 10.1177/20552076241297355.


CA-ViT: Contour-Guided and Augmented Vision Transformers to Enhance Glaucoma Classification Using Fundus Images.

Tohye T, Qin Z, Al-Antari M, Ukwuoma C, Lonseko Z, Gu Y Bioengineering (Basel). 2024; 11(9).

PMID: 39329629 PMC: 11429475. DOI: 10.3390/bioengineering11090887.


Motion Artifact Reduction Using U-Net Model with Three-Dimensional Simulation-Based Datasets for Brain Magnetic Resonance Images.

Kang S, Lee Y Bioengineering (Basel). 2024; 11(3).

PMID: 38534500 PMC: 10968316. DOI: 10.3390/bioengineering11030227.


2020 International brain-computer interface competition: A review.

Jeong J, Cho J, Lee Y, Lee S, Shin G, Kweon Y Front Hum Neurosci. 2022; 16:898300.

PMID: 35937679 PMC: 9354666. DOI: 10.3389/fnhum.2022.898300.