» Articles » PMID: 36014532

Production Review of Accelerator-Based Medical Isotopes

Overview
Journal Molecules
Publisher MDPI
Specialty Biology
Date 2022 Aug 26
PMID 36014532
Authors
Affiliations
Soon will be listed here.
Abstract

The production of reactor-based medical isotopes is fragile, which has meant supply shortages from time to time. This paper reviews alternative production methods in the form of cyclotrons, linear accelerators and neutron generators. Finally, the status of the production of medical isotopes in China is described.

Citing Articles

Radiotheranostic landscape: A review of clinical and preclinical development.

Tran H, Yamaguchi A, Manning H Eur J Nucl Med Mol Imaging. 2025; .

PMID: 39891713 DOI: 10.1007/s00259-025-07103-7.


Investigating Past, Present, and Future Trends on Interface Between Marine and Medical Research and Development: A Bibliometric Review.

Zamani M, Melnychuk T, Eisenhauer A, Gabler R, Schultz C Mar Drugs. 2025; 23(1).

PMID: 39852536 PMC: 11766621. DOI: 10.3390/md23010034.


Dissolution of Molybdenum in Hydrogen Peroxide: A Thermodynamic, Kinetic and Microscopic Study of a Green Process for Tc Production.

Cicconi F, Ubaldini A, Fiore A, Rizzo A, Cataldo S, Agostini P Molecules. 2023; 28(5).

PMID: 36903336 PMC: 10004273. DOI: 10.3390/molecules28052090.


Cyclotron Production of Gallium-68 Radiopharmaceuticals Using the Zn(p,n)Ga Reaction and Their Regulatory Aspects.

Ashhar Z, Ahmad Fadzil M, Othman M, Yusof N, Abdul Onny M, Mat Ail N Pharmaceutics. 2023; 15(1).

PMID: 36678699 PMC: 9867404. DOI: 10.3390/pharmaceutics15010070.

References
1.
Krebs S, ODonoghue J, Biegel E, Beattie B, Reidy D, Lyashchenko S . Comparison of Ga-DOTA-JR11 PET/CT with dosimetric Lu-satoreotide tetraxetan (Lu-DOTA-JR11) SPECT/CT in patients with metastatic neuroendocrine tumors undergoing peptide receptor radionuclide therapy. Eur J Nucl Med Mol Imaging. 2020; 47(13):3047-3057. PMC: 7644587. DOI: 10.1007/s00259-020-04832-9. View

2.
Langbein T, Weber W, Eiber M . Future of Theranostics: An Outlook on Precision Oncology in Nuclear Medicine. J Nucl Med. 2019; 60(Suppl 2):13S-19S. DOI: 10.2967/jnumed.118.220566. View

3.
McQuade P, Rowland D, Lewis J, Welch M . Positron-emitting isotopes produced on biomedical cyclotrons. Curr Med Chem. 2005; 12(7):807-18. DOI: 10.2174/0929867053507397. View

4.
Pandey M, Byrne J, Jiang H, Packard A, DeGrado T . Cyclotron production of (68)Ga via the (68)Zn(p,n)(68)Ga reaction in aqueous solution. Am J Nucl Med Mol Imaging. 2014; 4(4):303-10. PMC: 4074496. View

5.
Pillai M, Dash A, Knapp Jr F . Sustained availability of 99mTc: possible paths forward. J Nucl Med. 2012; 54(2):313-23. DOI: 10.2967/jnumed.112.110338. View