FBG-Based Soft System for Assisted Epidural Anesthesia: Design Optimization and Clinical Assessment

Overview
Specialty Biotechnology
Date 2022 Aug 25
PMID 36005041
Authors
Affiliations
Soon will be listed here.
Abstract

Fiber Bragg grating sensors (FBGs) are considered a valid sensing solution for a variety of medical applications. The last decade witnessed the exploitation of these sensors in applications ranging from minimally invasive surgery to biomechanics and monitoring physiological parameters. Recently, preliminary studies investigated the potential impact of FBGs in the management of epidural procedures by detecting when the needle reaches the epidural space with the loss of resistance (LOR) technique. In this article, we propose a soft and flexible FBG-based system capable of detecting the LOR, we optimized the solution by considering different designs and materials, and we assessed the feasibility of the optimized soft sensor (SS) in clinical settings. The proposed SS addresses some of the open challenges in the use of a sensing solution during epidural punctures: it has high sensitivity, it is non-invasive, the sensing element does not need to be inserted within the needle, and the clinician can follow the standard clinical practice. Our analysis highlights how the material and the design impact the system response, and thus its performance in this scenario. We also demonstrated the system's feasibility of detecting the LOR during epidural procedures.

Citing Articles

Recent Advances in Smart Epidural Spinal Needles.

Althobaiti M, Ali S, Hariri N, Hameed K, Alagl Y, Alzahrani N Sensors (Basel). 2023; 23(13).

PMID: 37447917 PMC: 10346758. DOI: 10.3390/s23136065.

References
1.
Moraca R, Sheldon D, Thirlby R . The role of epidural anesthesia and analgesia in surgical practice. Ann Surg. 2003; 238(5):663-73. PMC: 1356143. DOI: 10.1097/01.sla.0000094300.36689.ad. View

2.
Hogan Q . Epidural catheter tip position and distribution of injectate evaluated by computed tomography. Anesthesiology. 1999; 90(4):964-70. DOI: 10.1097/00000542-199904000-00006. View

3.
Hawkins J . Epidural analgesia for labor and delivery. N Engl J Med. 2010; 362(16):1503-10. DOI: 10.1056/NEJMct0909254. View

4.
Ambastha S, Umesh S, Dabir S, Asokan S . Spinal needle force monitoring during lumbar puncture using fiber Bragg grating force device. J Biomed Opt. 2016; 21(11):117002. DOI: 10.1117/1.JBO.21.11.117002. View

5.
Carassiti M, Pascarella G, Strumia A, Russo F, Papalia G, Cataldo R . Epidural Steroid Injections for Low Back Pain: A Narrative Review. Int J Environ Res Public Health. 2022; 19(1). PMC: 8744824. DOI: 10.3390/ijerph19010231. View