» Articles » PMID: 36001985

The OpenGATE Ecosystem for Monte Carlo Simulation in Medical Physics

Abstract

This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. Based on the shoulders of Geant4, the principal modules (geometry, physics, scorers) are described with brief descriptions of some key concepts (Volume, Actors, Digitizer). The main source code repositories are detailed together with the automated compilation and tests processes (Continuous Integration). We then described how the OpenGATE collaboration managed the collaborative development of about one hundred developers during almost 20 years. The impact of GATE on medical physics and cancer research is then summarized, and examples of a few key applications are given. Finally, future development perspectives are indicated.

Citing Articles

Combining PET and Compton imaging with edge-on CZT detectors for enhanced diagnostic capabilities.

Shoop G, Abbaszadeh S Adv Radiother Nucl Med. 2024; 2(2).

PMID: 39493887 PMC: 11529829. DOI: 10.36922/arnm.3330.


Monte Carlo methods for medical imaging research.

Lee H Biomed Eng Lett. 2024; 14(6):1195-1205.

PMID: 39465109 PMC: 11502642. DOI: 10.1007/s13534-024-00423-x.


An International Study of Factors Affecting Variability of Dosimetry Calculations, Part 3: Contribution from Calculating Absorbed Dose from Time-Integrated Activity.

Brosch-Lenz J, Kurkowska S, Frey E, Dewaraja Y, Sunderland J, Uribe C J Nucl Med. 2024; 65(8):1166-1172.

PMID: 38960715 PMC: 11294060. DOI: 10.2967/jnumed.123.267293.


Theranostics and artificial intelligence: new frontiers in personalized medicine.

Bilgin G, Bilgin C, Burkett B, Orme J, Childs D, Thorpe M Theranostics. 2024; 14(6):2367-2378.

PMID: 38646652 PMC: 11024845. DOI: 10.7150/thno.94788.


Radiobiological Assessment of Targeted Radionuclide Therapy with [Lu]Lu-PSMA-I&T in 2D vs. 3D Cell Culture Models.

Raitanen J, Barta B, Fuchs H, Hacker M, Balber T, Georg D Int J Mol Sci. 2023; 24(23).

PMID: 38069337 PMC: 10706939. DOI: 10.3390/ijms242317015.


References
1.
Tang W, Tang B, Li X, Wang Y, Li Z, Gao Y . Cellular S-value evaluation based on real human cell models using the GATE MC package. Appl Radiat Isot. 2020; 168:109509. DOI: 10.1016/j.apradiso.2020.109509. View

2.
Incerti S, Ivanchenko A, Karamitros M, Mantero A, Moretto P, Tran H . Comparison of GEANT4 very low energy cross section models with experimental data in water. Med Phys. 2010; 37(9):4692-708. DOI: 10.1118/1.3476457. View

3.
Grevillot L, Boersma D, Fuchs H, Aitkenhead A, Elia A, Bolsa M . Technical Note: GATE-RTion: a GATE/Geant4 release for clinical applications in scanned ion beam therapy. Med Phys. 2020; 47(8):3675-3681. DOI: 10.1002/mp.14242. View

4.
Grevillot L, Bertrand D, Dessy F, Freud N, Sarrut D . GATE as a GEANT4-based Monte Carlo platform for the evaluation of proton pencil beam scanning treatment plans. Phys Med Biol. 2012; 57(13):4223-44. DOI: 10.1088/0031-9155/57/13/4223. View

5.
Munoz E, Barrio J, Etxebeste A, Ortega P, Lacasta C, Oliver J . Performance evaluation of MACACO: a multilayer Compton camera. Phys Med Biol. 2017; 62(18):7321-7341. DOI: 10.1088/1361-6560/aa8070. View