» Articles » PMID: 36001667

Magnetic Soft Robotic Bladder for Assisted Urination

Overview
Journal Sci Adv
Specialties Biology
Science
Date 2022 Aug 24
PMID 36001667
Authors
Affiliations
Soon will be listed here.
Abstract

The poor contractility of the detrusor muscle in underactive bladders (UABs) fails to increase the pressure inside the UAB, leading to strenuous and incomplete urination. However, existing therapeutic strategies by modulating/repairing detrusor muscles, e.g., neurostimulation and regenerative medicine, still have low efficacy and/or adverse effects. Here, we present an implantable magnetic soft robotic bladder (MRB) that can directly apply mechanical compression to the UAB to assist urination. Composed of a biocompatible elastomer composite with optimized magnetic domains, the MRB enables on-demand contraction of the UAB when actuated by magnetic fields. A representative MRB for a UAB in a porcine model is demonstrated, and MRB-assisted urination is validated by in situ computed tomography imaging after 14-day implantation. The urodynamic tests show a series of successful urination with a high pressure increase and fast urine flow. Our work paves the way for developing MRB to assist urination for humans with UABs.

Citing Articles

Addressable and perceptible dynamic reprogram of ferromagnetic soft machines.

Sun Y, Sun B, Cui X, Li W, Zhang Y, He L Nat Commun. 2025; 16(1):2267.

PMID: 40050263 PMC: 11885537. DOI: 10.1038/s41467-025-57454-w.


Programmable spatial magnetization stereolithographic printing of biomimetic soft machines with thin-walled structures.

Meng X, Li S, Shen X, Tian C, Mao L, Xie H Nat Commun. 2024; 15(1):10442.

PMID: 39616160 PMC: 11608252. DOI: 10.1038/s41467-024-54773-2.


Water-Induced Shape-Locking Magnetic Robots.

Lou H, Wang Y, Sheng Y, Zhu H, Zhu S, Yu J Adv Sci (Weinh). 2024; 11(36):e2405021.

PMID: 39073727 PMC: 11423202. DOI: 10.1002/advs.202405021.


Wireless Magnetic Robot for Precise Hierarchical Control of Tissue Deformation.

Wang C, Zhao Z, Han J, Sharma A, Wang H, Zhang X Adv Sci (Weinh). 2024; 11(35):e2308619.

PMID: 39041885 PMC: 11425225. DOI: 10.1002/advs.202308619.


Continuum Robots and Magnetic Soft Robots: From Models to Interdisciplinary Challenges for Medical Applications.

Wang H, Mao Y, Du J Micromachines (Basel). 2024; 15(3).

PMID: 38542560 PMC: 10972085. DOI: 10.3390/mi15030313.


References
1.
Kim Y, Parada G, Liu S, Zhao X . Ferromagnetic soft continuum robots. Sci Robot. 2020; 4(33). DOI: 10.1126/scirobotics.aax7329. View

2.
Lum G, Ye Z, Dong X, Marvi H, Erin O, Hu W . Shape-programmable magnetic soft matter. Proc Natl Acad Sci U S A. 2016; 113(41):E6007-E6015. PMC: 5068264. DOI: 10.1073/pnas.1608193113. View

3.
Mahfouz W, Al Afraa T, Campeau L, Corcos J . Normal urodynamic parameters in women: part II--invasive urodynamics. Int Urogynecol J. 2011; 23(3):269-77. DOI: 10.1007/s00192-011-1585-y. View

4.
Levanovich P, Diokno A, Hasenau D, Lajiness M, Pruchnic R, Chancellor M . Intradetrusor injection of adult muscle-derived cells for the treatment of underactive bladder: pilot study. Int Urol Nephrol. 2015; 47(3):465-7. DOI: 10.1007/s11255-015-0924-1. View

5.
Chai T, Kudze T . New therapeutic directions to treat underactive bladder. Investig Clin Urol. 2017; 58(Suppl 2):S99-S106. PMC: 5740036. DOI: 10.4111/icu.2017.58.S2.S99. View