» Articles » PMID: 35924223

Biological Current Source Imaging Method Based on Acoustoelectric Effect: A Systematic Review

Overview
Journal Front Neurosci
Date 2022 Aug 4
PMID 35924223
Authors
Affiliations
Soon will be listed here.
Abstract

Neuroimaging can help reveal the spatial and temporal diversity of neural activity, which is of utmost importance for understanding the brain. However, conventional non-invasive neuroimaging methods do not have the advantage of high temporal and spatial resolution, which greatly hinders clinical and basic research. The acoustoelectric (AE) effect is a fundamental physical phenomenon based on the change of dielectric conductivity that has recently received much attention in the field of biomedical imaging. Based on the AE effect, a new imaging method for the biological current source has been proposed, combining the advantages of high temporal resolution of electrical measurements and high spatial resolution of focused ultrasound. This paper first describes the mechanism of the AE effect and the principle of the current source imaging method based on the AE effect. The second part summarizes the research progress of this current source imaging method in brain neurons, guided brain therapy, and heart. Finally, we discuss the problems and future directions of this biological current source imaging method. This review explores the relevant research literature and provides an informative reference for this potential non-invasive neuroimaging method.

References
1.
Lavandier B, Jossinet J, Cathignol D . Quantitative assessment of ultrasound-induced resistance change in saline solution. Med Biol Eng Comput. 2000; 38(2):150-5. DOI: 10.1007/BF02344769. View

2.
Daniels D, Sharabi S, Last D, Guez D, Salomon S, Zivli Z . Focused Ultrasound-Induced Suppression of Auditory Evoked Potentials in Vivo. Ultrasound Med Biol. 2018; 44(5):1022-1030. DOI: 10.1016/j.ultrasmedbio.2018.01.010. View

3.
Mickelsen S, Dudley B, Treat E, Barela J, Omdahl J, Kusumoto F . Survey of physician experience, trends and outcomes with atrial fibrillation ablation. J Interv Card Electrophysiol. 2005; 12(3):213-20. DOI: 10.1007/s10840-005-0621-6. View

4.
Olafsson R, Witte R, Huang S, ODonnell M . Ultrasound current source density imaging. IEEE Trans Biomed Eng. 2008; 55(7):1840-8. PMC: 2553012. DOI: 10.1109/TBME.2008.919115. View

5.
Xue G, Chen C, Lu Z, Dong Q . Brain Imaging Techniques and Their Applications in Decision-Making Research. Xin Li Xue Bao. 2010; 42(1):120-137. PMC: 2849100. DOI: 10.3724/SP.J.1041.2010.00120. View