» Articles » PMID: 35920384

Towards Sub-millisecond Cryo-EM Grid Preparation

Overview
Journal Faraday Discuss
Specialty Chemistry
Date 2022 Aug 3
PMID 35920384
Authors
Affiliations
Soon will be listed here.
Abstract

Sample preparation is still a significant problem for many single particle cryo-EM workflows and our understanding and developments in the area lag behind that of image processing and microscope design. Over the last few years there has been growing evidence that many of the problems which occur during sample preparation are during the time the sample resides within the thin film created during the conventional blotting process. In parallel, faster grid preparation approaches have been developed for time-resolved cryo-EM experiments allowing for non-equilibrium intermediates to be captured on the ms timescale. Therefore, an important question is how fast can we prepare suitable grids for imaging by cryo-EM and how much does this mitigate the problems observed in sample preparation? Here we use a novel approach which has been developed for time-resolved studies to produce grids on an estimated sub-1 ms timescale. While the method comes with its own challenges, a 3.8 Å reconstruction of apoferritin prepared with the ultrafast method shows that good resolutions can be achieved. Although several orders of magnitude faster than conventional approaches we show using a ribosome sample, that interactions with the air-water interface cannot be avoided with preferred orientations still present. Therefore, the work shows that faster reactions can be captured but poses the question whether speed is the answer to problems with sample preparation.

Citing Articles

Overcoming the preferred-orientation problem in cryo-EM with self-supervised deep learning.

Liu Y, Fan H, Hu J, Zhou Z Nat Methods. 2024; 22(1):113-123.

PMID: 39558095 DOI: 10.1038/s41592-024-02505-1.


CryoEM grid preparation: a closer look at advancements and impact of preparation mode and new approaches.

Hirst I, Thomas W, Davies R, Muench S Biochem Soc Trans. 2024; 52(3):1529-1537.

PMID: 38864435 PMC: 11346429. DOI: 10.1042/BST20231553.


Overcoming the preferred orientation problem in cryoEM with self-supervised deep-learning.

Liu Y, Fan H, Hu J, Zhou Z bioRxiv. 2024; .

PMID: 38645074 PMC: 11030451. DOI: 10.1101/2024.04.11.588921.

References
1.
Spudich J, Watt S . The regulation of rabbit skeletal muscle contraction. I. Biochemical studies of the interaction of the tropomyosin-troponin complex with actin and the proteolytic fragments of myosin. J Biol Chem. 1971; 246(15):4866-71. View

2.
Kontziampasis D, Klebl D, Iadanza M, Scarff C, Kopf F, Sobott F . A cryo-EM grid preparation device for time-resolved structural studies. IUCrJ. 2019; 6(Pt 6):1024-1031. PMC: 6830222. DOI: 10.1107/S2052252519011345. View

3.
Rohou A, Grigorieff N . CTFFIND4: Fast and accurate defocus estimation from electron micrographs. J Struct Biol. 2015; 192(2):216-21. PMC: 6760662. DOI: 10.1016/j.jsb.2015.08.008. View

4.
Millar N, Geeves M . The limiting rate of the ATP-mediated dissociation of actin from rabbit skeletal muscle myosin subfragment 1. FEBS Lett. 1983; 160(1-2):141-8. DOI: 10.1016/0014-5793(83)80954-5. View

5.
Noble A, Dandey V, Wei H, Brasch J, Chase J, Acharya P . Routine single particle CryoEM sample and grid characterization by tomography. Elife. 2018; 7. PMC: 5999397. DOI: 10.7554/eLife.34257. View