Abstract

Organ shape reconstruction based on a single-projection image during treatment has wide clinical scope, e.g., in image-guided radiotherapy and surgical guidance. We propose an image-to-graph convolutional network that achieves deformable registration of a three-dimensional (3D) organ mesh for a low-contrast two-dimensional (2D) projection image. This framework enables simultaneous training of two types of transformation: from the 2D projection image to a displacement map, and from the sampled per-vertex feature to a 3D displacement that satisfies the geometrical constraint of the mesh structure. Assuming application to radiation therapy, the 2D/3D deformable registration performance is verified for multiple abdominal organs that have not been targeted to date, i.e., the liver, stomach, duodenum, and kidney, and for pancreatic cancer. The experimental results show shape prediction considering relationships among multiple organs can be used to predict respiratory motion and deformation from digitally reconstructed radiographs with clinically acceptable accuracy.

Citing Articles

Real-time CBCT imaging and motion tracking via a single arbitrarily-angled x-ray projection by a joint dynamic reconstruction and motion estimation (DREME) framework.

Shao H, Mengke T, Pan T, Zhang Y Phys Med Biol. 2025; 70(2.

PMID: 39746309 PMC: 11747166. DOI: 10.1088/1361-6560/ada519.


Real-time CBCT Imaging and Motion Tracking via a Single Arbitrarily-angled X-ray Projection by a Joint Dynamic Reconstruction and Motion Estimation (DREME) Framework.

Shao H, Mengke T, Pan T, Zhang Y ArXiv. 2024; .

PMID: 39398221 PMC: 11469417.


Real-time liver motion estimation via deep learning-based angle-agnostic X-ray imaging.

Shao H, Li Y, Wang J, Jiang S, Zhang Y Med Phys. 2023; 50(11):6649-6662.

PMID: 37922461 PMC: 10629841. DOI: 10.1002/mp.16691.


2D/3D Non-Rigid Image Registration via Two Orthogonal X-ray Projection Images for Lung Tumor Tracking.

Dong G, Dai J, Li N, Zhang C, He W, Liu L Bioengineering (Basel). 2023; 10(2).

PMID: 36829638 PMC: 9951849. DOI: 10.3390/bioengineering10020144.


Real-time liver tumor localization via combined surface imaging and a single x-ray projection.

Shao H, Li Y, Wang J, Jiang S, Zhang Y Phys Med Biol. 2023; 68(6).

PMID: 36731143 PMC: 10394117. DOI: 10.1088/1361-6560/acb889.