» Articles » PMID: 35890846

Intra- and Inter-Day Reliability of the NIRS Portamon Device After Three Induced Muscle Ischemias

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Jul 27
PMID 35890846
Authors
Affiliations
Soon will be listed here.
Abstract

(1) Background: Near-infrared spectroscopy (NIRS) is an innovative and non-invasive technology used to investigate muscular oxygenation. The aim of this study is to assess the within- and between-session reliability of the NIRS Portamon (Artinis, Elst, Netherlands) device following three sets of induced muscle ischemia. (2) Methods: Depending on the experimental group (G1, G2 or G3), a cuff was inflated three times on the left upper arm to 50 mmHg (G1), systolic blood pressure (SBP) + 50 mmHg (G2) or 250 mmHg (G3). Maximum, minimum and reoxygenation rate values were assessed after each occlusion phase, using a Portamon device placed on the left brachioradialis. Reliability was assessed with intraclass correlation coefficient (ICC) value and ICC 95% confidence interval (CI-95%), coefficient of variation (CV) and standard error of measurement (SEM) (3) Results: Our results showed a good to excellent reliability for maximums and minimums within-session. However, the reoxygenation rate within sessions as well as measurements between sessions cannot predominantly show good reliability. (4) Conclusions: Multiple measurements of maximums and minimums within a single session appeared to be reliable which shows that only one measurement is necessary to assess these parameters. However, it is necessary to be cautious with a comparison of maximum, minimum and reoxygenation rate values between sessions.

Citing Articles

Near-Infrared Spectroscopy Allows for Monitoring of Bone Fracture Healing via Changes in Oxygenation.

Nowicki C, Ganse B J Funct Biomater. 2024; 15(12).

PMID: 39728184 PMC: 11677907. DOI: 10.3390/jfb15120384.


A short review of application of near-infrared spectroscopy (NIRS) for the assessment of microvascular post-occlusive reactive hyperaemia (PORH) in skeletal muscle.

Hendrick E, Jamieson A, Chiesa S, Hughes A, Jones S Front Physiol. 2024; 15:1480720.

PMID: 39665053 PMC: 11633644. DOI: 10.3389/fphys.2024.1480720.


Optimizing brain protection after cardiac arrest: advanced strategies and best practices.

Iavarone I, Donadello K, Cammarota G, DAgostino F, Pellis T, Roman-Pognuz E Interface Focus. 2024; 14(6):20240025.

PMID: 39649449 PMC: 11620827. DOI: 10.1098/rsfs.2024.0025.


Effects of occlusion pressure on hemodynamic responses recorded by near-infrared spectroscopy across two visits.

Desanlis J, Gordon D, French C, Calveyrac C, Cottin F, Gernigon M Front Physiol. 2024; 15:1441239.

PMID: 39324105 PMC: 11422206. DOI: 10.3389/fphys.2024.1441239.


Reliability and Convergent Validity of Endurance Indices Derived from Near-Infrared Spectroscopy and Electromyography during a Bilateral Hanging Task in Amateur Rock Climbers.

Kwong W, Li J, Lui C, Luk H, Lau K, Seaby R J Funct Morphol Kinesiol. 2024; 9(3).

PMID: 39311269 PMC: 11417833. DOI: 10.3390/jfmk9030161.


References
1.
Kime R, Karlsen T, Nioka S, Lech G, Madsen O, Saeterdal R . Discrepancy between cardiorespiratory system and skeletal muscle in elite cyclists after hypoxic training. Dyn Med. 2003; 2(1):4. PMC: 212707. DOI: 10.1186/1476-5918-2-4. View

2.
Mol A, Woltering J, Colier W, Maier A, Meskers C, van Wezel R . Sensitivity and reliability of cerebral oxygenation responses to postural changes measured with near-infrared spectroscopy. Eur J Appl Physiol. 2019; 119(5):1117-1125. PMC: 6469633. DOI: 10.1007/s00421-019-04101-0. View

3.
McLay K, Gilbertson J, Pogliaghi S, Paterson D, Murias J . Vascular responsiveness measured by tissue oxygen saturation reperfusion slope is sensitive to different occlusion durations and training status. Exp Physiol. 2016; 101(10):1309-1318. DOI: 10.1113/EP085843. View

4.
Zhang C, Hodges B, McCully K . Reliability and reproducibility of a four arterial occlusions protocol for assessing muscle oxidative metabolism at rest and after exercise using near-infrared spectroscopy. Physiol Meas. 2020; 41(6):065002. DOI: 10.1088/1361-6579/ab921c. View

5.
Lacroix S, Gayda M, Gremeaux V, Juneau M, Tardif J, Nigam A . Reproducibility of near-infrared spectroscopy parameters measured during brachial artery occlusion and reactive hyperemia in healthy men. J Biomed Opt. 2012; 17(7):077010. DOI: 10.1117/1.JBO.17.7.077010. View