» Articles » PMID: 35886529

Ozone Eliminates SARS-CoV-2 from Difficult-to-Clean Office Supplies and Clinical Equipment

Abstract

(1) Background: Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) continues to cause profound health, economic, and social problems worldwide. The management and disinfection of materials used daily in health centers and common working environments have prompted concerns about the control of coronavirus disease 2019 (COVID-19) infection risk. Ozone is a powerful oxidizing agent that has been widely used in disinfection processes for decades. The aim of this study was to assess the optimal conditions of ozone treatment for the elimination of heat-inactivated SARS-CoV-2 from office supplies (personal computer monitors, keyboards, and computer mice) and clinical equipment (continuous positive airway pressure tubes and personal protective equipment) that are difficult to clean. (2) Methods: The office supplies and clinical equipment were contaminated in an area of 1 cm with 1 × 10 viral units of a heat-inactivated SARS-CoV-2 strain, then treated with ozone using two different ozone devices: a specifically designed ozonation chamber (for low-medium ozone concentrations over large volumes) and a clinical ozone generator (for high ozone concentrations over small volumes). SARS-CoV-2 gene detection was carried out using quantitative real-time polymerase chain reaction (RT-qPCR). (3) Results: At high ozone concentrations over small surfaces, the ozone eliminated SARS-CoV-2 RNA in short time periods-i.e., 10 min (at 4000 ppm) or less. The optimum ozone concentration over large volumes was 90 ppm for 120 min in ambient conditions (24 °C and 60-75% relative humidity). (4) Conclusions: This study showed that the appropriate ozone concentration and exposure time eliminated heat-inactivated SARS-CoV-2 RNA from the surfaces of different widely used clinical and office supplies, decreasing their risk of transmission, and improving their reutilization. Ozone may provide an additional tool to control the spread of the COVID-19 pandemic.

Citing Articles

Optimizing heat inactivation for SARS-CoV-2 at 95 °C and its implications: A standardized approach.

Mak G, Lau S, Wong K, Than E, Ng A, Hung D Heliyon. 2024; 10(8):e28371.

PMID: 38655330 PMC: 11035938. DOI: 10.1016/j.heliyon.2024.e28371.


Ozone Disinfection for Elimination of Bacteria and Degradation of SARS-CoV2 RNA for Medical Environments.

Westover C, Rahmatulloev S, Danko D, Afshin E, OHara N, Ounit R Genes (Basel). 2023; 14(1).

PMID: 36672826 PMC: 9858956. DOI: 10.3390/genes14010085.

References
1.
Albert S, Amarilla A, Trollope B, Sng J, Setoh Y, Deering N . Assessing the potential of unmanned aerial vehicle spraying of aqueous ozone as an outdoor disinfectant for SARS-CoV-2. Environ Res. 2021; 196:110944. PMC: 7908847. DOI: 10.1016/j.envres.2021.110944. View

2.
Carraturo F, Del Giudice C, Morelli M, Cerullo V, Libralato G, Galdiero E . Persistence of SARS-CoV-2 in the environment and COVID-19 transmission risk from environmental matrices and surfaces. Environ Pollut. 2020; 265(Pt B):115010. PMC: 7280109. DOI: 10.1016/j.envpol.2020.115010. View

3.
Ataei-Pirkooh A, Alavi A, Kianirad M, Bagherzadeh K, Ghasempour A, Pourdakan O . Destruction mechanisms of ozone over SARS-CoV-2. Sci Rep. 2021; 11(1):18851. PMC: 8458291. DOI: 10.1038/s41598-021-97860-w. View

4.
Murray B, Ohmine S, Tomer D, Jensen K, Johnson F, Kirsi J . Virion disruption by ozone-mediated reactive oxygen species. J Virol Methods. 2008; 153(1):74-7. DOI: 10.1016/j.jviromet.2008.06.004. View

5.
Manjunath S, Sakar M, Katapadi M, Balakrishna R . Recent case studies on the use of ozone to combat coronavirus: Problems and perspectives. Environ Technol Innov. 2020; 21:101313. PMC: 7733684. DOI: 10.1016/j.eti.2020.101313. View