» Articles » PMID: 35885476

Diagnostic Accuracy of Loop-Mediated Isothermal Amplification Assay for Group B Streptococcus Detection in Recto-Vaginal Swab: Comparison with Polymerase Chain Reaction Test and Conventional Culture

Overview
Specialty Radiology
Date 2022 Jul 27
PMID 35885476
Authors
Affiliations
Soon will be listed here.
Abstract

A rapid method for obtaining group B streptococcus (GBS) screening results has been required in the obstetric field. We aimed to determine the diagnostic performance of the Loop-Mediated Isothermal Amplification (LAMP) assay is acceptable compared to the existing polymerase chain reaction (PCR) assay. The study involved 527 pregnant women aged 19 to 44 years. Rectovaginal swabs were collected between 35 and 37 weeks of gestation or prior to impending preterm births or term labor without GBS screening. We presented the diagnostic performance of the LAMP assay with a 95% confidence interval (CI) compared to the PCR and microbiological culture. In total, 115 (21.8%), 115 (21.8%) and 23 (4.4%) patients showed positive results using the LAMP, PCR assay and microbiological culture method, respectively. The LAMP assay showed 100% sensitivity (95% CI, 96.8-100.0), 100% specificity (95% CI, 99.1-100.0) and 100% diagnostic accuracy (95% CI, 99.3-100.0) with the reference being the PCR assay. Meanwhile, the LAMP assay showed 87.0% sensitivity (95% CI, 71.0-100.0), 81.2% specificity (95% CI, 77.6-84.7), and 81.4% diagnostic accuracy (95% CI, 78.0-84.8) with the microbiological culture as a reference. This study presented the LAMP assay as an acceptable method for GBS screening with a similar performance to the existing PCR method.

Citing Articles

To evaluate the performance of simultaneous amplification and testing assay for group B Streptococcus detection: comparison with real-time PCR and ddPCR assays.

Lu L, Chen Y, Wang Q, Gao J, Ying C Ann Clin Microbiol Antimicrob. 2024; 23(1):65.

PMID: 39026373 PMC: 11264765. DOI: 10.1186/s12941-024-00726-y.


Updates on Group B Infection in the Field of Obstetrics and Gynecology.

Choi Y, Han H, Chong G, Le T, Nguyen H, Lee O Microorganisms. 2022; 10(12).

PMID: 36557651 PMC: 9780959. DOI: 10.3390/microorganisms10122398.

References
1.
Gonzalez-Gonzalez E, Lara-Mayorga I, Rodriguez-Sanchez I, Zhang Y, Martinez-Chapa S, Trujillo-de Santiago G . Colorimetric loop-mediated isothermal amplification (LAMP) for cost-effective and quantitative detection of SARS-CoV-2: the change in color in LAMP-based assays quantitatively correlates with viral copy number. Anal Methods. 2021; 13(2):169-178. DOI: 10.1039/d0ay01658f. View

2.
Silbert S, Rocchetti T, Gostnell A, Kubasek C, Widen R . Detection of Group B Streptococcus Directly from Collected ESwab Samples by Use of the BD Max GBS Assay. J Clin Microbiol. 2016; 54(6):1660-1663. PMC: 4879306. DOI: 10.1128/JCM.00445-16. View

3.
Kim D, Min B, Jung E, Byun J, Jeong D, Lee K . Prevalence of group B streptococcus colonization in pregnant women in a tertiary care center in Korea. Obstet Gynecol Sci. 2018; 61(5):575-583. PMC: 6137023. DOI: 10.5468/ogs.2018.61.5.575. View

4.
Khan M, Faiz A, Ashshi A . Maternal colonization of group B streptococcus: prevalence, associated factors and antimicrobial resistance. Ann Saudi Med. 2015; 35(6):423-7. PMC: 6074477. DOI: 10.5144/0256-4947.2015.423. View

5.
Towers C, Rumney P, Asrat T, Preslicka C, Ghamsary M, Nageotte M . The accuracy of late third-trimester antenatal screening for group B streptococcus in predicting colonization at delivery. Am J Perinatol. 2010; 27(10):785-90. DOI: 10.1055/s-0030-1254237. View