» Articles » PMID: 35875875

Automated Generation of 0D and 1D Reduced-order Models of Patient-specific Blood Flow

Overview
Publisher Wiley
Date 2022 Jul 25
PMID 35875875
Authors
Affiliations
Soon will be listed here.
Abstract

Three-dimensional (3D) cardiovascular fluid dynamics simulations typically require hours to days of computing time on a high-performance computing cluster. One-dimensional (1D) and lumped-parameter zero-dimensional (0D) models show great promise for accurately predicting blood bulk flow and pressure waveforms with only a fraction of the cost. They can also accelerate uncertainty quantification, optimization, and design parameterization studies. Despite several prior studies generating 1D and 0D models and comparing them to 3D solutions, these were typically limited to either 1D or 0D and a singular category of vascular anatomies. This work proposes a fully automated and openly available framework to generate and simulate 1D and 0D models from 3D patient-specific geometries, automatically detecting vessel junctions and stenosis segments. Our only input is the 3D geometry; we do not use any prior knowledge from 3D simulations. All computational tools presented in this work are implemented in the open-source software platform SimVascular. We demonstrate the reduced-order approximation quality against rigid-wall 3D solutions in a comprehensive comparison with N = 72 publicly available models from various anatomies, vessel types, and disease conditions. Relative average approximation errors of flows and pressures typically ranged from 1% to 10% for both 1D and 0D models, measured at the outlets of terminal vessel branches. In general, 0D model errors were only slightly higher than 1D model errors despite requiring only a third of the 1D runtime. Automatically generated ROMs can significantly speed up model development and shift the computational load from high-performance machines to personal computers.

Citing Articles

Enhancing cardiac assessments: accurate and efficient prediction of quantitative fractional flow reserve.

Eskandari A, Malek S, Jabbari A, Javari K, Rahmati N, Nikbakhtian B Front Bioeng Biotechnol. 2025; 13:1438253.

PMID: 39931137 PMC: 11808135. DOI: 10.3389/fbioe.2025.1438253.


FSGe: A fast and strongly-coupled 3D fluid-solid-growth interaction method.

Pfaller M, Latorre M, Schwarz E, Gerosa F, Szafron J, Humphrey J Comput Methods Appl Mech Eng. 2024; 431.

PMID: 39430055 PMC: 11484312. DOI: 10.1016/j.cma.2024.117259.


Deforming Patient-Specific Models of Vascular Anatomies to Represent Stent Implantation via Extended Position Based Dynamics.

Pham J, Kong F, James D, Feinstein J, Marsden A Cardiovasc Eng Technol. 2024; 15(6):760-774.

PMID: 39354259 PMC: 11653221. DOI: 10.1007/s13239-024-00752-z.


Personalized and uncertainty-aware coronary hemodynamics simulations: From Bayesian estimation to improved multi-fidelity uncertainty quantification.

Menon K, Zanoni A, Khan O, Geraci G, Nieman K, Schiavazzi D ArXiv. 2024; .

PMID: 39279834 PMC: 11398544.


Dissecting contributions of pulmonary arterial remodeling to right ventricular afterload in pulmonary hypertension.

Neelakantan S, Mendiola E, Zambrano B, Vang A, Myers K, Zhang P bioRxiv. 2024; .

PMID: 39229168 PMC: 11370336. DOI: 10.1101/2024.08.18.608471.


References
1.
Blanco P, Bulant C, Muller L, Maso Talou G, Bezerra C, Lemos P . Comparison of 1D and 3D Models for the Estimation of Fractional Flow Reserve. Sci Rep. 2018; 8(1):17275. PMC: 6250665. DOI: 10.1038/s41598-018-35344-0. View

2.
Stergiopulos N, Young D, Rogge T . Computer simulation of arterial flow with applications to arterial and aortic stenoses. J Biomech. 1992; 25(12):1477-88. DOI: 10.1016/0021-9290(92)90060-e. View

3.
Esmaily Moghadam M, Migliavacca F, Vignon-Clementel I, Hsia T, Marsden A . Optimization of shunt placement for the Norwood surgery using multi-domain modeling. J Biomech Eng. 2012; 134(5):051002. DOI: 10.1115/1.4006814. View

4.
Matthys K, Alastruey J, Peiro J, Khir A, Segers P, Verdonck P . Pulse wave propagation in a model human arterial network: assessment of 1-D numerical simulations against in vitro measurements. J Biomech. 2007; 40(15):3476-86. DOI: 10.1016/j.jbiomech.2007.05.027. View

5.
Sengupta D, Kahn A, Burns J, Sankaran S, Shadden S, Marsden A . Image-based modeling of hemodynamics in coronary artery aneurysms caused by Kawasaki disease. Biomech Model Mechanobiol. 2011; 11(6):915-32. PMC: 6091534. DOI: 10.1007/s10237-011-0361-8. View