Background: To determine the repeatability of corneal topography measurements in severe dry eye disease (DED). A comparison of corneal topography parameters between severe DED and healthy subjects was a secondary goal of this study.

Methods: Sixty-nine patients with severe DED and 46 healthy subjects were enrolled in the study. All participants underwent repeated corneal topography measurements with Pentacam (Oculus, Germany) within a half hour time. Both eyes of the participants were used in statistical analysis. A further subcategorization of severe DED patients was performed according to Ocular Surface Disease Index (OSDI) scores: 32-50, 51-70 and 71-100. The repeatability of corneal parameters was assessed with correlation coefficients (CC).

Results: The mean age of dry eye patients and healthy subjects were 40.8 ± 13.2 (17-66) and 39.8 ± 8.2 (18-61) years (p:0.604) respectively. No significant differences were found between severe DED and control groups according to analysed corneal parameters in both eyes (p:>0.05). All CCs were greater than 0.9 in severe DED group (p:<0.001). All CCs were also greater than 0.9 in severe DED patients among different OSDI groups (p:<0.001).

Conclusions: Corneal topography measurements are highly repeatable in severe DED with Pentacam. This is the first report about this topic. Nonetheless, further studies are needed with different topography devices for validation.

Citing Articles

Assessment of punctal metrics and tear meniscus height in epiphora: clinical insights and diagnostic potential.

Sevimli N, Iren E, Taydas G, Azarbaz M Jpn J Ophthalmol. 2025; .

PMID: 40056355 DOI: 10.1007/s10384-025-01182-7.


Swept-source optical coherence tomography in ocular surface diseases: anterior segment analysis repeatability and its limits.

Recchioni A, Venkataraman A, Rauz S, Dominguez-Vicent A Front Med (Lausanne). 2024; 11:1385294.

PMID: 39156694 PMC: 11327131. DOI: 10.3389/fmed.2024.1385294.

References
1.
BarKana Y, Gerber Y, Elbaz U, Schwartz S, Ken-Dror G, Avni I . Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry. J Cataract Refract Surg. 2005; 31(9):1729-35. DOI: 10.1016/j.jcrs.2005.03.058. View

2.
Zemova E, Eppig T, Seitz B, Toropygin S, Arnold S, Langenbucher A . Interaction between topographic/tomographic parameters and dry eye disease in keratoconus patients. Curr Eye Res. 2013; 39(1):1-8. DOI: 10.3109/02713683.2013.798667. View

3.
Fujisawa K, Sasaki K . Changes in light scattering intensity of the transparent lenses of subjects selected from population-based surveys depending on age: analysis through Scheimpflug images. Ophthalmic Res. 1995; 27(2):89-101. DOI: 10.1159/000267604. View

4.
Lemp M . Report of the National Eye Institute/Industry workshop on Clinical Trials in Dry Eyes. CLAO J. 1995; 21(4):221-32. View

5.
Xu Z, Peng M, Jiang J, Yang C, Zhu W, Lu F . Reliability of Pentacam HR Thickness Maps of the Entire Cornea in Normal, Post-Laser In Situ Keratomileusis, and Keratoconus Eyes. Am J Ophthalmol. 2015; 162:74-82.e1. DOI: 10.1016/j.ajo.2015.11.008. View