» Articles » PMID: 35813151

Diagnostic Accuracy of Magnetic Resonance Imaging for Partial Tears of the Long Head of the Biceps Tendon in Patients with Rotator Cuff Tears

Overview
Journal JSES Int
Date 2022 Jul 11
PMID 35813151
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Magnetic resonance imaging (MRI) is useful for diagnosing shoulder diseases preoperatively. However, detection of partial tears of the long head of the biceps tendon (LHBT) using current clinical tests and imaging modalities is difficult. We aimed to evaluate the accuracy of radial-slice MRI for diagnosing partial tears of the LHBT. We hypothesized that radial-slice MRI may be a valuable diagnostic tool for assessing diagnosing tears of the LHBT.

Methods: We retrospectively investigated 118 patients who underwent shoulder arthroscopy for rotator cuff tears. Intraoperative LHBT findings were compared with the identification of partial tears of the LHBT on conventional-slice MRI and radial-slice MRI, using a 3.0-T system. We calculated sensitivity, specificity, accuracy, and positive and negative predictive values for the detection of LHBT tears. Inter- and intraobserver reliability for radial-slice MRI was calculated using kappa statistics.

Results: We diagnosed 69 patients (58%) without any LHBT tears and 49 with partial tears (42%), arthroscopically. Sensitivity, specificity, accuracy, and positive and negative predictive values of conventional-slice MRI for detection of partial tears of the LHBT were 52%, 94%, 78%, 92%, and 58%, respectively. Radial-slice MRI had 84% sensitivity, 90% specificity, 86% accuracy, and 92% positive and 80% negative predictive values for partial tears of the LHBT. Inter- and intraobserver reliability for radial-slice MRI was 0.69 and 0.74, respectively, corresponding to high reproducibility and defined as good.

Conclusion: Radial-slice MRI demonstrated significantly higher sensitivity than conventional-slice MRI. These results indicate that radial-slice MRI is useful for diagnosing LHBT partial tears.

Citing Articles

Microwave Digital Twin Prototype for Shoulder Injury Detection.

Borzooei S, Tournier P, Dolean V, Migliaccio C Sensors (Basel). 2024; 24(20).

PMID: 39460143 PMC: 11510924. DOI: 10.3390/s24206663.


MRI findings and clinical testing for preoperative diagnosis of long head of the biceps pathology.

Gallinet D, Antoni M, Berhouet J, Charousset C, Guery J J Exp Orthop. 2024; 11(4):e70050.

PMID: 39415802 PMC: 11480518. DOI: 10.1002/jeo2.70050.


Current Understanding and New Advances in the Surgical Management of Reparable Rotator Cuff Tears: A Scoping Review.

Eckers F, Loske S, Ek E, Muller A J Clin Med. 2023; 12(5).

PMID: 36902499 PMC: 10003213. DOI: 10.3390/jcm12051713.

References
1.
Boileau P, Ahrens P, Hatzidakis A . Entrapment of the long head of the biceps tendon: the hourglass biceps--a cause of pain and locking of the shoulder. J Shoulder Elbow Surg. 2004; 13(3):249-57. DOI: 10.1016/j.jse.2004.01.001. View

2.
De Maeseneer M, Boulet C, Pouliart N, Kichouh M, Buls N, Verhelle F . Assessment of the long head of the biceps tendon of the shoulder with 3T magnetic resonance arthrography and CT arthrography. Eur J Radiol. 2011; 81(5):934-9. DOI: 10.1016/j.ejrad.2011.01.121. View

3.
Belanger V, Dupuis F, Leblond J, Roy J . Accuracy of examination of the long head of the biceps tendon in the clinical setting: A systematic review. J Rehabil Med. 2019; 51(7):479-491. DOI: 10.2340/16501977-2563. View

4.
Dubrow S, Streit J, Shishani Y, Robbin M, Gobezie R . Diagnostic accuracy in detecting tears in the proximal biceps tendon using standard nonenhancing shoulder MRI. Open Access J Sports Med. 2014; 5:81-7. PMC: 4011903. DOI: 10.2147/OAJSM.S58225. View

5.
Razmjou H, Fournier-Gosselin S, Christakis M, Pennings A, Elmaraghy A, Holtby R . Accuracy of magnetic resonance imaging in detecting biceps pathology in patients with rotator cuff disorders: comparison with arthroscopy. J Shoulder Elbow Surg. 2015; 25(1):38-44. DOI: 10.1016/j.jse.2015.06.020. View