Abstract

Background And Purpose: Anatomical surveillance during ion-beam therapy is the basis for an effective tumor treatment and optimal organ at risk (OAR) sparing. Synthetic computed tomography (sCT) based on magnetic resonance imaging (MRI) can replace the X-ray based planning CT (X-rayCT) in photon radiotherapy and improve the workflow efficiency without additional imaging dose. The extension to carbon-ion radiotherapy is highly challenging; complex patient positioning, unique anatomical situations, distinct horizontal and vertical beam incidence directions, and limited training data are only few problems. This study gives insight into the possibilities and challenges of using sCTs in carbon-ion therapy.

Materials And Methods: For head and neck patients immobilised with thermoplastic masks 30 clinically applied actively scanned carbon-ion treatment plans on 15 CTs comprising 60 beams were analyzed. Those treatment plans were re-calculated on MRI based sCTs which were created employing a 3D U-Net. Dose differences and carbon-ion spot displacements between sCT and X-rayCT were evaluated on a patient specific basis.

Results: Spot displacement analysis showed a peak displacement by 0.2 cm caused by the immobilisation mask not measurable with the MRI. 95.7% of all spot displacements were located within 1 cm. For the clinical target volume (CTV) the median D agreed within -0.2% (-1.3 to 1.4%), while the median D differed up to 4.2% (-1.3 to 25.3%) comparing the dose distribution on the X-rayCT and the sCT. OAR deviations depended strongly on the position and the dose gradient. For three patients no deterioration of the OAR parameters was observed. Other patients showed large deteriorations, e.g. for one patient D of the chiasm differed by 28.1%.

Conclusion: The usage of sCTs opens several new questions, concluding that we are not ready yet for an MR-only workflow in carbon-ion therapy, as envisaged in photon therapy. Although omitting the X-rayCT seems unfavourable in the case of carbon-ion therapy, an sCT could be advantageous for monitoring, re-planning, and adaptation.

Citing Articles

"Under the hood": artificial intelligence in personalized radiotherapy.

Gianoli C, De Bernardi E, Parodi K BJR Open. 2024; 6(1):tzae017.

PMID: 39104573 PMC: 11299549. DOI: 10.1093/bjro/tzae017.


A review of the clinical introduction of 4D particle therapy research concepts.

Knausl B, Belotti G, Bertholet J, Daartz J, Flampouri S, Hoogeman M Phys Imaging Radiat Oncol. 2024; 29:100535.

PMID: 38298885 PMC: 10828898. DOI: 10.1016/j.phro.2024.100535.


Synthetic CTs for MRI-only brain RT treatment: integration of immobilization systems.

Masitho S, Grigo J, Brandt T, Lambrecht U, Szkitsak J, Weiss A Strahlenther Onkol. 2023; 199(8):739-748.

PMID: 37285037 PMC: 10361877. DOI: 10.1007/s00066-023-02090-w.


Synthetic CT in Carbon Ion Radiotherapy of the Abdominal Site.

Parrella G, Vai A, Nakas A, Garau N, Meschini G, Camagni F Bioengineering (Basel). 2023; 10(2).

PMID: 36829745 PMC: 9951997. DOI: 10.3390/bioengineering10020250.

References
1.
Paddick I . A simple scoring ratio to index the conformity of radiosurgical treatment plans. Technical note. J Neurosurg. 2001; 93 Suppl 3:219-22. DOI: 10.3171/jns.2000.93.supplement. View

2.
Maspero M, Bentvelzen L, Savenije M, Guerreiro F, Seravalli E, Janssens G . Deep learning-based synthetic CT generation for paediatric brain MR-only photon and proton radiotherapy. Radiother Oncol. 2020; 153:197-204. DOI: 10.1016/j.radonc.2020.09.029. View

3.
Neppl S, Landry G, Kurz C, Hansen D, Hoyle B, Stocklein S . Evaluation of proton and photon dose distributions recalculated on 2D and 3D Unet-generated pseudoCTs from T1-weighted MR head scans. Acta Oncol. 2019; 58(10):1429-1434. DOI: 10.1080/0284186X.2019.1630754. View

4.
Dinkla A, Florkow M, Maspero M, Savenije M, Zijlstra F, Doornaert P . Dosimetric evaluation of synthetic CT for head and neck radiotherapy generated by a patch-based three-dimensional convolutional neural network. Med Phys. 2019; 46(9):4095-4104. DOI: 10.1002/mp.13663. View

5.
Spadea M, Maspero M, Zaffino P, Seco J . Deep learning based synthetic-CT generation in radiotherapy and PET: A review. Med Phys. 2021; 48(11):6537-6566. DOI: 10.1002/mp.15150. View