Anthropomorphic Cardiac Phantom for Dynamic SPECT

Overview
Journal J Nucl Cardiol
Date 2022 Jun 27
PMID 35760983
Authors
Affiliations
Soon will be listed here.
Abstract

As myocardial blood flow measurement (MBF) in SPECT systems became recently available, significant effort has been devoted to its validation. For that purpose, we have developed a cardiac phantom that is able to mimic physiological radiotracer variation in the left ventricle cavity and in the myocardium, while performing beating-like motion. The new phantom is integrated inside a standard anthropomorphic torso allowing a realistic tissue attenuation and gamma-ray scattering METHODS AND RESULTS: A mechanical cardiac phantom was integrated in a commercially available anthropomorphic torso. Using a GE Discovery 530c SPECT, measurements were performed. It was found that gamma-ray attenuation effects are significant and limit the MBF measurements to global/three-vessel resolution. Dynamic SPECT experiments were performed to validate MBF accuracy and showed mean relative error of 14%. Finally, the effect of varying radiotracer dose on the accuracy of dynamic SPECT was studied CONCLUSIONS: A dynamic cardiac phantom has been developed and successfully integrated in a standard SPECT torso. A good agreement was found between SPECT-reported MBF values and the expected results. Despite increased noise-to-signal ratio when radiotracer doses were reduced, MBF uncertainty did not increase significantly down to very low doses, thanks to the temporal integration of the activity during the measurement.

Citing Articles

Evaluating the accuracy of planar gated blood pool processing software using simulated patient studies.

Pieters H, van Staden J, du Raan H, Nel M, Engelbrecht G Heliyon. 2024; 10(17):e37299.

PMID: 39296234 PMC: 11408074. DOI: 10.1016/j.heliyon.2024.e37299.


Validation of advanced hybrid SPECT/CT system using dynamic anthropomorphic cardiac phantom.

Gelbart E, Krakovich A, Sherm Y, Rabin G, Ratner H, Scheinowitz M Ann Nucl Med. 2024; 38(11):919-926.

PMID: 39210201 PMC: 11489191. DOI: 10.1007/s12149-024-01966-w.


A simulation-based phantom model for generating synthetic mitral valve image data-application to MRI acquisition planning.

Manini C, Nemchyna O, Akansel S, Walczak L, Tautz L, Kolbitsch C Int J Comput Assist Radiol Surg. 2023; 19(3):553-569.

PMID: 37679657 PMC: 10881710. DOI: 10.1007/s11548-023-03012-y.

References
1.
Lima R, Watson D, Goode A, Siadaty M, Ragosta M, Beller G . Incremental value of combined perfusion and function over perfusion alone by gated SPECT myocardial perfusion imaging for detection of severe three-vessel coronary artery disease. J Am Coll Cardiol. 2003; 42(1):64-70. DOI: 10.1016/s0735-1097(03)00562-x. View

2.
Herzog B, Husmann L, Valenta I, Gaemperli O, Siegrist P, Tay F . Long-term prognostic value of 13N-ammonia myocardial perfusion positron emission tomography added value of coronary flow reserve. J Am Coll Cardiol. 2009; 54(2):150-6. DOI: 10.1016/j.jacc.2009.02.069. View

3.
Bocher M, Blevis I, Tsukerman L, Shrem Y, Kovalski G, Volokh L . A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential. Eur J Nucl Med Mol Imaging. 2010; 37(10):1887-902. PMC: 2933031. DOI: 10.1007/s00259-010-1488-z. View

4.
Ben-Haim S, Murthy V, Breault C, Allie R, Sitek A, Roth N . Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study. J Nucl Med. 2013; 54(6):873-9. PMC: 3951831. DOI: 10.2967/jnumed.112.109652. View

5.
Wells R, Timmins R, Klein R, Lockwood J, Marvin B, deKemp R . Dynamic SPECT measurement of absolute myocardial blood flow in a porcine model. J Nucl Med. 2014; 55(10):1685-91. DOI: 10.2967/jnumed.114.139782. View