» Articles » PMID: 35744297

In Vitro Biodegradation of A-C:H:SiO Films on Ti-6Al-4V Alloy

Overview
Publisher MDPI
Date 2022 Jun 24
PMID 35744297
Authors
Affiliations
Soon will be listed here.
Abstract

This paper focuses mainly on the in vitro study of a five-week biodegradation of a-C:H:SiO films of different thickness, obtained by plasma-assisted chemical vapor deposition onto Ti-6Al-4V alloy substrate using its pulsed bipolar biasing. In vitro immersion of a-C:H:SiO films in a solution of 0.9% NaCl was used. It is shown how the a-C:H:SiO film thickness (0.5-3 µm) affects the surface morphology, adhesive strength, and Na and Cl precipitation on the film surface from the NaCl solution. With increasing film thickness, the roughness indices are reducing a little. The adhesive strength of the a-C:H:SiO films to metal substrate corresponds to quality HF1 (0.5 µm in thickness) and HF2-HF3 (1.5-3 µm in thickness) of the Rockwell hardness test (VDI 3198) that defines strong interfacial adhesion and is usually applied in practice. The morphometric analysis of the film surface shows that on a-C:H:SiO-coated Ti-6Al-4V alloy surface, the area occupied by the grains of sodium chloride is lower than on the uncoated surface. The reduction in the ion precipitation from 0.9% NaCl onto the film surface depended on the elemental composition of the surface layer conditioned by the thickness growth of the a-C:H:SiO film. Based on the results of energy dispersive X-ray spectroscopy, the multiple regression equations are suggested to explain the effect of the elemental composition of the a-C:H:SiO film on the decreased Na and Cl precipitation. As a result, the a-C:H:SiO films successfully combine good adhesion strength and rare ion precipitation and thus are rather promising for medical applications on cardiovascular stents and/or friction parts of heart pumps.

References
1.
Vetsch J, Paulsen S, Muller R, Hofmann S . Effect of fetal bovine serum on mineralization in silk fibroin scaffolds. Acta Biomater. 2014; 13:277-85. DOI: 10.1016/j.actbio.2014.11.025. View

2.
Randeniya L, Bendavid A, Martin P, Amin M, Preston E, Magdon Ismail F . Incorporation of Si and SiO(x) into diamond-like carbon films: impact on surface properties and osteoblast adhesion. Acta Biomater. 2009; 5(5):1791-7. DOI: 10.1016/j.actbio.2009.01.013. View

3.
Okpalugo T, Murphy H, Ogwu A, Abbas G, Ray S, Maguire P . Human microvascular endothelial cellular interaction with atomic N-doped DLC compared with Si-doped DLC thin films. J Biomed Mater Res B Appl Biomater. 2006; 78(2):222-9. DOI: 10.1002/jbm.b.30459. View

4.
Bociaga D, Sobczyk-Guzenda A, Komorowski P, Balcerzak J, Jastrzebski K, Przybyszewska K . Surface Characteristics and Biological Evaluation of Si-DLC Coatings Fabricated Using Magnetron Sputtering Method on Ti6Al7Nb Substrate. Nanomaterials (Basel). 2019; 9(6). PMC: 6630968. DOI: 10.3390/nano9060812. View

5.
Meireles G, de Abreu L, Forte A, Sumita M, Sumita J, Aliaga J . Randomized comparative study of diamond-like carbon coated stainless steel stent versus uncoated stent implantation in patients with coronary artery disease. Arq Bras Cardiol. 2007; 88(4):390-5. DOI: 10.1590/s0066-782x2007000400004. View