» Articles » PMID: 35695478

Rapid Quantification of MicroRNA-375 Through One-pot Primer-generating Rolling Circle Amplification

Overview
Journal Analyst
Specialty Chemistry
Date 2022 Jun 13
PMID 35695478
Authors
Affiliations
Soon will be listed here.
Abstract

A recent surge of interest in microRNA has been driven by its discovery as a circulating biomarker of disease, with many diagnostic test platforms currently under development. Alternatives to widely used microRNA quantification methods such as quantitative reverse transcriptase PCR (qRT-PCR) are needed for use in portable and point-of-care devices which are incompatible with complex sample processing workflows and thermal cycling. Rolling circle amplification (RCA) is a one-pot assay technique which directly amplifies nucleic acids using sequence-specific microRNA priming to initiate a single-step isothermal reaction that is compatible with simple devices. Sensitivity remains a limitation of RCA methods, however, and detection limits do not typically reach the femtomolar level in which microRNA targets are present in blood. RCA assays have previously been improved by digestion of the amplification products using a nicking endonuclease to exponentially generate new reaction primers. Here we describe how a ligation-free version of this technique performed in a single tube can be used to improve the limit of detection for microRNA-375, an important blood biomarker for prostate cancer. Endonuclease addition changes a linear process into an exponential amplification reaction which results in a 61-fold improvement of the limit of detection (5.9 fM), a dynamic range wider than 5-log(10), and a shorter reaction time. By eliminating the need for microRNA reverse transcription and thermal cycling, this single-step one-pot method provides a more rapid and simplified alternative to qRT-PCR for ultrasensitive microRNA quantification in blood extracts.

Citing Articles

Design and Optimization of Isothermal Gene Amplification for Generation of High-Gain Oligonucleotide Products by MicroRNAs.

Lee J, Han J, Song Y, Gu B, Kim E ACS Meas Sci Au. 2024; 4(6):737-750.

PMID: 39713023 PMC: 11660000. DOI: 10.1021/acsmeasuresciau.4c00063.


Coupling Exponential to Linear Amplification for Endpoint Quantitative Analysis.

Kieffer C, Rondelez Y, Gines G Adv Sci (Weinh). 2024; 11(21):e2309386.

PMID: 38593401 PMC: 11151046. DOI: 10.1002/advs.202309386.

References
1.
Buchan B, Ledeboer N . Emerging technologies for the clinical microbiology laboratory. Clin Microbiol Rev. 2014; 27(4):783-822. PMC: 4187641. DOI: 10.1128/CMR.00003-14. View

2.
Tuma R, Beaudet M, Jin X, Jones L, Cheung C, Yue S . Characterization of SYBR Gold nucleic acid gel stain: a dye optimized for use with 300-nm ultraviolet transilluminators. Anal Biochem. 1999; 268(2):278-88. DOI: 10.1006/abio.1998.3067. View

3.
Murakami T, Sumaoka J, Komiyama M . Sensitive RNA detection by combining three-way junction formation and primer generation-rolling circle amplification. Nucleic Acids Res. 2011; 40(3):e22. PMC: 3273829. DOI: 10.1093/nar/gkr909. View

4.
Pritchard C, Cheng H, Tewari M . MicroRNA profiling: approaches and considerations. Nat Rev Genet. 2012; 13(5):358-69. PMC: 4517822. DOI: 10.1038/nrg3198. View

5.
Van Rooij E . The art of microRNA research. Circ Res. 2011; 108(2):219-34. DOI: 10.1161/CIRCRESAHA.110.227496. View