» Articles » PMID: 35684742

Microwave Antenna System for Muscle Rupture Imaging with a Lossy Gel to Reduce Multipath Interference

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Jun 10
PMID 35684742
Authors
Affiliations
Soon will be listed here.
Abstract

Injuries to the hamstring muscles are an increasing problem in sports. Imaging plays a key role in diagnosing and managing athletes with muscle injuries, but there are several problems with conventional imaging modalities with respect to cost and availability. We hypothesized that microwave imaging could provide improved availability and lower costs and lead to improved and more accurate diagnostics. In this paper, a semicircular microwave imaging array with eight antennae was investigated. A key component in this system is the novel antenna design, which is based on a monopole antenna and a lossy gel. The purpose of the gel is to reduce the effects of multipath signals and improve the imaging quality. Several different gels have been manufactured and evaluated in imaging experiments. For comparison, corresponding simulations were performed. The results showed that the gels can effectively reduce the multipath signals and the imaging experiments resulted in significantly more stable and repeatable reconstructions when a lossy gel was used compared to when an almost non-lossy gel was used.

References
1.
Chang J, Paulsen K, Meaney P, Fanning M . Non-invasive thermal assessment of tissue phantoms using an active near field microwave imaging technique. Int J Hyperthermia. 1999; 14(6):513-34. DOI: 10.3109/02656739809018252. View

2.
Bahramiabarghouei H, Porter E, Santorelli A, Gosselin B, Popovic M, Rusch L . Flexible 16 Antenna Array for Microwave Breast Cancer Detection. IEEE Trans Biomed Eng. 2015; 62(10):2516-25. DOI: 10.1109/TBME.2015.2434956. View

3.
Chu S, Rho M . Hamstring Injuries in the Athlete: Diagnosis, Treatment, and Return to Play. Curr Sports Med Rep. 2016; 15(3):184-90. PMC: 5003616. DOI: 10.1249/JSR.0000000000000264. View

4.
Meaney P, Paulsen K . Addressing Multipath Signal Corruption in Microwave Tomography and the Influence on System Design and Algorithm Development. Open Access J Biomed Eng Biosci. 2019; 1(1). PMC: 6395052. DOI: 10.32474/OAJBEB.2018.01.000102. View

5.
Persson M, Fhager A, Dobsicek Trefna H, Yu Y, McKelvey T, Pegenius G . Microwave-based stroke diagnosis making global prehospital thrombolytic treatment possible. IEEE Trans Biomed Eng. 2014; 61(11):2806-17. DOI: 10.1109/TBME.2014.2330554. View