» Articles » PMID: 3566511

Micromotion of Conventionally Cemented All-polyethylene Tibial Components in Total Knee Replacements. A Roentgen Stereophotogrammetric Analysis of Migration and Inducible Displacement

Overview
Specialty Orthopedics
Date 1987 Jan 1
PMID 3566511
Citations 5
Authors
Affiliations
Soon will be listed here.
Abstract

Micromotion of the tibial component in 27 knee arthroplasties for gonarthrosis, three of which were regarded as failures for reasons other than mechanical loosening, was studied using high-resolution roentgen stereophotogrammetric analysis (RSA). Migration over time was found in all cases, ranging from 0.2 to 2.1 mm. The majority of the cases showed migration during the first year only, while a minority migrated continuously during the period studied. The latter group showed more migration even after 1 year. All cases showed inducible displacement in response to external forces, ranging from 0.2 to 1.0 mm. The micromotion correlated with the age of the patient but not with other demographic parameters. Alignment or component position did not correlate with the micromotion. All cases but one had developed a radiolucent zone, and it was concluded that the micromotion occurred in the soft tissue interface between bone and cement. Such micromotion is a normal finding in cemented tibial components in knee arthroplasty.

Citing Articles

RSA migration of total knee replacements.

Pijls B, Plevier J, Nelissen R Acta Orthop. 2018; 89(3):320-328.

PMID: 29508661 PMC: 6055769. DOI: 10.1080/17453674.2018.1443635.


Dynamic RSA for the evaluation of inducible micromotion of Oxford UKA during step-up and step-down motion.

Horsager K, Kaptein B, Romer L, Jorgensen P, Stilling M Acta Orthop. 2017; 88(3):275-281.

PMID: 28067099 PMC: 5434595. DOI: 10.1080/17453674.2016.1274592.


Prospective randomised clinical trial assessing subsidence and rotation, using radiostereometric analysis, of two modular cementless femoral stems (Global K2 and Apex).

Edmondson M, Ebert J, Nivbrant O, Wood D J Orthop. 2014; 11(2):96-102.

PMID: 25104894 PMC: 4118571. DOI: 10.1016/j.jor.2014.02.001.


Early migration of tibial components is associated with late revision: a systematic review and meta-analysis of 21,000 knee arthroplasties.

Pijls B, Valstar E, Nouta K, Plevier J, Fiocco M, Middeldorp S Acta Orthop. 2012; 83(6):614-24.

PMID: 23140091 PMC: 3555454. DOI: 10.3109/17453674.2012.747052.


The influence of metal backing in unicompartmental tibial component fixation. An in vivo roentgen stereophotogrammetric analysis of micromotion.

Ryd L, Lindstrand A, Stenstrom A, Selvik G Arch Orthop Trauma Surg. 1992; 111(3):148-54.

PMID: 1586577 DOI: 10.1007/BF00388089.

References
1.
AHLBACK S . Osteoarthrosis of the knee. A radiographic investigation. Acta Radiol Diagn (Stockh). 1968; :Suppl 277:7-72. View

2.
Jonsson G . Compartmental arthroplasty for gonarthrosis. Acta Orthop Scand Suppl. 1981; 193:1-110. DOI: 10.3109/17453678109154867. View

3.
Hori R, Lewis J . Mechanical properties of the fibrous tissue found at the bone-cement interface following total joint replacement. J Biomed Mater Res. 1982; 16(6):911-27. DOI: 10.1002/jbm.820160615. View

4.
Schneider R, FREIBERGER R, Ghelman B, Ranawat C . Radiologic evaluation of painful joint prostheses. Clin Orthop Relat Res. 1982; (170):156-68. View

5.
Harris W . Advances in total hip arthroplasty. The metal-backed acetabular component. Clin Orthop Relat Res. 1984; (183):4-11. View