» Articles » PMID: 35645644

Rethinking the Coronal Anatomic Axis of the Distal Tibia for Intramedullary Nail Placement: A Cadaveric Study

Overview
Journal HSS J
Date 2022 Jun 1
PMID 35645644
Authors
Affiliations
Soon will be listed here.
Abstract

Recent studies have reported that targeting a center-center position at the distal tibia during intramedullary nailing (IMN) may result in malalignment. Although not fully understood, this observation suggests that the coronal anatomic center of the tibia may not correspond to the center of the distal tibia articular surface. : To identify the coronal anatomic axis of the distal tibia that corresponds to an ideal start site for IMN placement utilizing intact cadaveric tibiae. : IMN placement was performed in 9 fresh frozen cadaveric tibiae. A guidewire was used to identify the ideal start site in the proximal tibia and an opening reamer allowed access to the canal. Each nail was then advanced without the use of a reaming rod until exiting the distal tibia plafond. Cadaveric and radiographic measurements were performed to determine the center of the nail exit site in the coronal plane. : Cadaveric and radiographic measurements identified the IMN exit site to correspond with the lateral 59.5% and 60.4% of the plafond, respectively. : Tibial nails inserted using an ideal start site have an endpoint that corresponds roughly to the junction of the lateral and middle third of the plafond. Further studies are warranted to better understand the impact of IMN endpoint placement on the functional and radiographic outcomes of tibia shaft fractures.

Citing Articles

Distal Tibia Apex Posterior Angulation: A Normal Anatomic Variant Related to Hindfoot Alignment With Side-to-Side Symmetry.

Megerian M, Schimizzi G, Barth K, LaValva S, Klinger C, Dziadosz D J Am Acad Orthop Surg Glob Res Rev. 2023; 7(6).

PMID: 37319362 PMC: 10566894. DOI: 10.5435/JAAOSGlobal-D-23-00076.


Does the distal nail position impact the rates of misalignment and bone union in distal tibial fractures?.

Garabano G, Jaime A, Perez Alamino L, Taleb J, Rodriguez J, Pesciallo C Eur J Orthop Surg Traumatol. 2023; 33(8):3365-3371.

PMID: 37127816 DOI: 10.1007/s00590-023-03566-2.

References
1.
Triantafillou K, Barcak E, Villarreal A, Collinge C, Perez E . Proper Distal Placement of Tibial Nail Improves Rate of Malalignment for Distal Tibia Fractures. J Orthop Trauma. 2017; 31(12):e407-e411. DOI: 10.1097/BOT.0000000000000989. View

2.
Bhandari M, Guyatt G, Tornetta 3rd P, Schemitsch E, Swiontkowski M, Sanders D . Randomized trial of reamed and unreamed intramedullary nailing of tibial shaft fractures. J Bone Joint Surg Am. 2008; 90(12):2567-78. PMC: 2663330. DOI: 10.2106/JBJS.G.01694. View

3.
Buehler K, Green J, Woll T, Duwelius P . A technique for intramedullary nailing of proximal third tibia fractures. J Orthop Trauma. 1997; 11(3):218-23. DOI: 10.1097/00005131-199704000-00014. View

4.
Riedel M, Gonzalez T, Kwon J . How much is too much? A guide to appropriately bending ball tip guide wires when using intramedullary nails for the treatment of lower extremity long bone fractures. Injury. 2016; 47(4):954-7. DOI: 10.1016/j.injury.2015.12.023. View

5.
Freedman E, Johnson E . Radiographic analysis of tibial fracture malalignment following intramedullary nailing. Clin Orthop Relat Res. 1995; (315):25-33. View