Impact of Self-coiling Catheters for Continuous Popliteal Sciatic Block on Postoperative Pain Level and Dislocation Rate: a Randomized Controlled Trial

Overview
Journal BMC Anesthesiol
Publisher Biomed Central
Specialty Anesthesiology
Date 2022 May 24
PMID 35610566
Authors
Affiliations
Soon will be listed here.
Abstract

Background: Dislocation of catheters within the tissue is a challenge in continuous regional anesthesia. A novel self-coiling catheter design is available and has demonstrated a lower dislocation rate in a cadaver model. The dislocation rate and effect on postoperative pain of these catheters in vivo has yet to be determined and were the subjects of this investigation.

Methods: After ethics committee approval 140 patients undergoing elective distal lower limb surgery were enrolled in this prospective randomized controlled trial. Preoperatively, patients were randomly assigned and received either the conventional (n = 70) or self-coiling catheter (n = 70) for ultrasound-guided popliteal sciatic nerve block in short axis view and by the in-plane approach from lateral to medial. The primary outcome was pain intensity after surgery and on the following three postoperative days. Secondary outcomes investigated were dislocation rate in situ determined by sonography, catheter movement visible from outside, opioid consumption as well as leakage at the puncture site.

Results: All catheters were successfully inserted. The study population of self-coiling catheters had significantly lower mean numeric rating scale values than the reference cohort on the first (p = 0.01) and second postoperative days (p < 0.01). Sonographic evaluation demonstrated, 42 standard catheters (60%) and 10 self-coiling catheters (14.3%) were dislocated in situ within the first three postoperative days. The externally visible movement of the catheters at insertion site did not differ significantly between groups through the third postoperative day. The opioid consumption was significantly lower in the self-coiling catheter group on the day of surgery and on the second and third postoperative days (p = 0.04, p = 0.03 and p = 0.04, respectively).

Conclusion: The self-coiling catheter offers a better postoperative pain control and a lower dislocation rate within the tissue when blocking the popliteal sciatic nerve compared to a conventional catheter. Further trials in large patient cohorts are warranted to investigate the potential beneficial effects of self-coiling catheters for other localisations and other application techniques.

Trial Registration: The trial was registered at German Clinical Trials Register (DRKS) on 08/04/2020 ( DRKS00020938 , retrospectively registered).

Citing Articles

Coiling of echogenic perineural catheters with integral stylet: A proof-of-concept randomized control trial in a sciatic nerve block simulator and a pilot study in orthopaedic-trauma patients.

Saranteas T, Poulogiannopoulou E, Riga M, Panagouli K, Mavrogenis A, Papadimos T F1000Res. 2024; 13:1103.

PMID: 39639915 PMC: 11617819. DOI: 10.12688/f1000research.155381.2.


Minimizing risk of iatrogenic nerve injury during peroneus longus tendon autograft harvest: a cadaveric study at different ankle or knee positions.

Wu S, Rothrauff B, Li J, He J Knee Surg Sports Traumatol Arthrosc. 2022; 31(6):2454-2460.

PMID: 36251045 DOI: 10.1007/s00167-022-07202-0.

References
1.
Ip V, Rockley M, Tsui B . The catheter-over-needle assembly offers greater stability and less leakage compared with the traditional counterpart in continuous interscalene nerve blocks: a randomized patient-blinded study. Can J Anaesth. 2013; 60(12):1272-3. DOI: 10.1007/s12630-013-0032-6. View

2.
Kim T, Howard S, Funck N, Harrison T, Walters T, Wagner M . A randomized comparison of long-axis and short-axis imaging for in-plane ultrasound-guided popliteal-sciatic perineural catheter insertion. J Anesth. 2014; 28(6):854-60. DOI: 10.1007/s00540-014-1832-8. View

3.
Fisker A, Iversen B, Christensen S, Linde F, Nielsen K, Borglum J . Combined saphenous and sciatic catheters for analgesia after major ankle surgery: a double-blinded randomized controlled trial. Can J Anaesth. 2015; 62(8):875-82. DOI: 10.1007/s12630-015-0379-y. View

4.
Albrecht E, Bathory I, Fournier N, Jacot-Guillarmod A, Farron A, Brull R . Reduced hemidiaphragmatic paresis with extrafascial compared with conventional intrafascial tip placement for continuous interscalene brachial plexus block: a randomized, controlled, double-blind trial. Br J Anaesth. 2017; 118(4):586-592. DOI: 10.1093/bja/aex050. View

5.
Andersen H, Andersen S, Tranum-Jensen J . Injection inside the paraneural sheath of the sciatic nerve: direct comparison among ultrasound imaging, macroscopic anatomy, and histologic analysis. Reg Anesth Pain Med. 2012; 37(4):410-4. DOI: 10.1097/AAP.0b013e31825145f3. View