» Articles » PMID: 35599691

Investigation of Functional Near-infrared Spectroscopy Signal Quality and Development of the Hemodynamic Phase Correlation Signal

Overview
Journal Neurophotonics
Date 2022 May 23
PMID 35599691
Authors
Affiliations
Soon will be listed here.
Abstract

There is a longstanding recommendation within the field of fNIRS to use oxygenated ( ) and deoxygenated (HHb) hemoglobin when analyzing and interpreting results. Despite this, many fNIRS studies do focus on only. Previous work has shown that on its own is susceptible to systemic interference and results may mostly reflect that rather than functional activation. Studies using both and HHb to draw their conclusions do so with varying methods and can lead to discrepancies between studies. The combination of and HHb has been recommended as a method to utilize both signals in analysis. We present the development of the hemodynamic phase correlation (HPC) signal to combine and HHb as recommended to utilize both signals in the analysis. We use synthetic and experimental data to evaluate how the HPC and current signals used for fNIRS analysis compare. About 18 synthetic datasets were formed using resting-state fNIRS data acquired from 16 channels over the frontal lobe. To simulate fNIRS data for a block-design task, we superimposed a synthetic task-related hemodynamic response to the resting state data. This data was used to develop an HPC-general linear model (GLM) framework. Experiments were conducted to investigate the performance of each signal at different SNR and to investigate the effect of false positives on the data. Performance was based on each signal's mean -value across channels. Experimental data recorded from 128 participants across 134 channels during a finger-tapping task were used to investigate the performance of multiple signals [ , HHb, HbT, HbD, correlation-based signal improvement (CBSI), and HPC] on real data. Signal performance was evaluated on its ability to localize activation to a specific region of interest. Results from varying the SNR show that the HPC signal has the highest performance for high SNRs. The CBSI performed the best for medium-low SNR. The next analysis evaluated how false positives affect the signals. The analyses evaluating the effect of false positives showed that the HPC and CBSI signals reflect the effect of false positives on and HHb. The analysis of real experimental data revealed that the HPC and HHb signals provide localization to the primary motor cortex with the highest accuracy. We developed a new hemodynamic signal (HPC) with the potential to overcome the current limitations of using and HHb separately. Our results suggest that the HPC signal provides comparable accuracy to HHb to localize functional activation while at the same time being more robust against false positives.

Citing Articles

From lab to life: challenges and perspectives of fNIRS for haemodynamic-based neurofeedback in real-world environments.

Klein F, Kohl S, Luhrs M, Mehler D, Sorger B Philos Trans R Soc Lond B Biol Sci. 2024; 379(1915):20230087.

PMID: 39428887 PMC: 11513164. DOI: 10.1098/rstb.2023.0087.


Optimizing spatial specificity and signal quality in fNIRS: an overview of potential challenges and possible options for improving the reliability of real-time applications.

Klein F Front Neuroergon. 2024; 5:1286586.

PMID: 38903906 PMC: 11188482. DOI: 10.3389/fnrgo.2024.1286586.


Using cross-correlation analysis of multi-channel near infrared spectroscopy to assess the hemodynamic response to cupping therapy.

Liau B, Lung C, Hernandez M, Mo P, Li Y, Guo J Biomed Opt Express. 2023; 14(9):4455-4467.

PMID: 37791272 PMC: 10545202. DOI: 10.1364/BOE.493897.


Using functional near-infrared spectroscopy to measure prefrontal cortex activity during dual-task walking and navigated walking: A feasibility study.

Kvist A, Bezuidenhout L, Johansson H, Albrecht F, Ekman U, Moulaee Conradsson D Brain Behav. 2023; 13(4):e2948.

PMID: 36917560 PMC: 10097069. DOI: 10.1002/brb3.2948.

References
1.
Gruber T, Debracque C, Ceravolo L, Igloi K, Marin Bosch B, Fruhholz S . Human Discrimination and Categorization of Emotions in Voices: A Functional Near-Infrared Spectroscopy (fNIRS) Study. Front Neurosci. 2020; 14:570. PMC: 7290129. DOI: 10.3389/fnins.2020.00570. View

2.
Curtin A, Ayaz H, Tang Y, Sun J, Wang J, Tong S . Enhancing neural efficiency of cognitive processing speed via training and neurostimulation: An fNIRS and TMS study. Neuroimage. 2019; 198:73-82. DOI: 10.1016/j.neuroimage.2019.05.020. View

3.
Carey L, Abbott D, Egan G, Tochon-Danguy H, Donnan G . The functional neuroanatomy and long-term reproducibility of brain activation associated with a simple finger tapping task in older healthy volunteers: a serial PET study. Neuroimage. 2000; 11(2):124-44. DOI: 10.1006/nimg.1999.0522. View

4.
Drenckhahn C, Koch S, Dummler J, Kohl-Bareis M, Steinbrink J, Dreier J . A validation study of the use of near-infrared spectroscopy imaging in primary and secondary motor areas of the human brain. Epilepsy Behav. 2015; 49:118-25. DOI: 10.1016/j.yebeh.2015.04.006. View

5.
van der Kant A, Biro S, Levelt C, Huijbregts S . Negative affect is related to reduced differential neural responses to social and non-social stimuli in 5-to-8-month-old infants: A functional near-infrared spectroscopy-study. Dev Cogn Neurosci. 2017; 30:23-30. PMC: 6969126. DOI: 10.1016/j.dcn.2017.12.003. View