Abstract

Purpose: Aseptic loosening is a common cause of implant failure following total knee arthroplasty (TKA). Cement penetration depth is a known factor that determines an implant's "strength" and plays an important role in preventing aseptic loosening. Tourniquet use is thought to facilitate cement penetration, but its use has mixed reviews. The aim of this study was to compare cement penetration depth between tourniquet and tourniquet-less TKA patients.

Methods: A multicenter retrospective review was conducted. Patients were randomized preoperatively to undergo TKA with or without the use of an intraoperative tourniquet. The variables collected were cement penetration measurements in millimeters (mm) within a 1-month post-operative period, length of stay (LOS), and baseline demographics. Measurements were taken by two independent raters and made in accordance to the zones described by the Knee Society Radiographic Evaluation System and methodology used in previous studies.

Results: A total of 357 TKA patients were studied. No demographic differences were found between tourniquet (n = 189) and tourniquet-less (n = 168) cohorts. However, the tourniquet cohort had statistically, but not clinically, greater average cement penetration depth [2.4 ± 0.6 mm (range 1.2-4.1 mm) vs. 2.2 ± 0.5 mm (range 1.0-4.3 mm, p = 0.01)]. Moreover, the tourniquet cohort had a significantly greater proportion of patients with an average penetration depth within the accepted zone of 2 mm or greater (78.9% vs. 67.3%, p = 0.02).

Conclusion: Tourniquet use does not affect average penetration depth but increases the likelihood of achieving optimal cement penetration depth. Further study is warranted to determine whether this increased likelihood of optimal cement penetration depth yields lower revision rates.

Citing Articles

Comparison of medium- and long-term total knee arthroplasty follow-up with or without tourniquet.

Zhong Q, Yang H, Qi R, Zhang T, Zhan J, Yao Y BMC Musculoskelet Disord. 2025; 26(1):205.

PMID: 40016694 PMC: 11866867. DOI: 10.1186/s12891-025-08462-w.


Tourniquet and/or Adductor Canal Block Use Confer No Additional Early Quadriceps Weakness Following Total Knee Arthroplasty: An Analysis of 203 Patients.

Lawrence K, Konopka J, Arraut J, Bieganowski T, Schwarzkopf R, Rozell J Iowa Orthop J. 2025; 44(2):67-76.

PMID: 39811180 PMC: 11726490.


Impact of tourniquet use in total knee arthroplasty on functional recovery and postoperative pain: a prospective study.

Beckers G, Mazy D, Manche E, Geulette B Arch Orthop Trauma Surg. 2023; 144(3):1361-1367.

PMID: 38102333 DOI: 10.1007/s00402-023-05158-5.

References
1.
Parsch D, Kruger M, Moser M, Geiger F . Follow-up of 11-16 years after modular fixed-bearing TKA. Int Orthop. 2008; 33(2):431-5. PMC: 2899054. DOI: 10.1007/s00264-008-0543-x. View

2.
Curtin B, Malkani A, Lau E, Kurtz S, Ong K . Revision after total knee arthroplasty and unicompartmental knee arthroplasty in the Medicare population. J Arthroplasty. 2012; 27(8):1480-6. DOI: 10.1016/j.arth.2012.02.019. View

3.
Gapinski Z, Yee E, Kraus K, Deckard E, Meneghini R . The Effect of Tourniquet Use and Sterile Carbon Dioxide Gas Bone Preparation on Cement Penetration in Primary Total Knee Arthroplasty. J Arthroplasty. 2019; 34(8):1634-1639. DOI: 10.1016/j.arth.2019.03.050. View

4.
Kutzner I, Hallan G, Hol P, Furnes O, Gothesen O, Figved W . Early aseptic loosening of a mobile-bearing total knee replacement. Acta Orthop. 2017; 89(1):77-83. PMC: 5810837. DOI: 10.1080/17453674.2017.1398012. View

5.
Hampton C, Berliner Z, Nguyen J, Mendez L, Smith S, Joseph A . Aseptic Loosening at the Tibia in Total Knee Arthroplasty: A Function of Cement Mantle Quality?. J Arthroplasty. 2020; 35(6S):S190-S196. DOI: 10.1016/j.arth.2020.02.028. View