» Articles » PMID: 35534595

Experimental Validation of a Voxel-based Finite Element Model Simulating Femoroplasty of Lytic Lesions in the Proximal Femur

Overview
Journal Sci Rep
Specialty Science
Date 2022 May 9
PMID 35534595
Authors
Affiliations
Soon will be listed here.
Abstract

Femoroplasty is a procedure where bone cement is injected percutaneously into a weakened proximal femur. Uncertainty exists whether femoroplasty provides sufficient mechanical strengthening to prevent fractures in patients with femoral bone metastases. Finite element models are promising tools to evaluate the mechanical effectiveness of femoroplasty, but a thorough validation is required. This study validated a voxel-based finite element model against experimental data from eight pairs of human cadaver femurs with artificial metastatic lesions. One femur from each pair was left untreated, while the contralateral femur was augmented with bone cement. Finite element models accurately predicted the femoral strength in the defect (R = 0.96) and augmented (R = 0.93) femurs. The modelled surface strain distributions showed a good qualitative match with results from digital image correlation; yet, quantitatively, only moderate correlation coefficients were found for the defect (mean R = 0.78) and augmented (mean R = 0.76) femurs. This was attributed to the presence of vessel holes in the femurs and the jagged surface representation of our voxel-based models. Despite some inaccuracies in the surface measurements, the FE models accurately predicted the global bone strength and qualitative deformation behavior, both before and after femoroplasty. Hence, they can offer a useful biomechanical tool to assist clinicians in assessing the need for prophylactic augmentation in patients with metastatic bone disease, as well as in identifying suitable patients for femoroplasty.

Citing Articles

Mechanical Gains Associated With Virtual Prophylactic Intramedullary Nail Fixation in Femurs With Metastatic Disease.

Johnson J, Figueroa A, Brouillette M, Miller B, Goetz J Iowa Orthop J. 2024; 43(2):70-78.

PMID: 38213856 PMC: 10777699.

References
1.
Groning F, Liu J, Fagan M, OHiggins P . Validating a voxel-based finite element model of a human mandible using digital speckle pattern interferometry. J Biomech. 2009; 42(9):1224-9. DOI: 10.1016/j.jbiomech.2009.03.025. View

2.
Philipp T, Mikula J, Doung Y, Gundle K . Is There an Association Between Prophylactic Femur Stabilization and Survival in Patients with Metastatic Bone Disease?. Clin Orthop Relat Res. 2020; 478(3):540-546. PMC: 7145091. DOI: 10.1097/CORR.0000000000000803. View

3.
Katz Y, Yosibash Z . New insights on the proximal femur biomechanics using Digital Image Correlation. J Biomech. 2020; 101:109599. DOI: 10.1016/j.jbiomech.2020.109599. View

4.
Faulkner K, Gluer C, Grampp S, Genant H . Cross-calibration of liquid and solid QCT calibration standards: corrections to the UCSF normative data. Osteoporos Int. 1993; 3(1):36-42. DOI: 10.1007/BF01623175. View

5.
Eggermont F, van der Wal G, Westhoff P, Laar A, de Jong M, Rozema T . Patient-specific finite element computer models improve fracture risk assessments in cancer patients with femoral bone metastases compared to clinical guidelines. Bone. 2019; 130:115101. DOI: 10.1016/j.bone.2019.115101. View