» Articles » PMID: 35527529

Anterior Ocular Biometrics Using Placido-scanning-slit System, Rotating Scheimpflug Tomography, and Swept-source Optical Coherence Tomography

Overview
Specialty Ophthalmology
Date 2022 May 9
PMID 35527529
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare anterior biometry measurements using placido-scanning-slit topography, rotating Scheimpflug tomography, and swept-source optical coherence tomography.

Methods: A retrospective review consisted of 80 eyes of 49 participants who underwent anterior chamber depth (ACD), central corneal thickness (CCT), and keratometry examination on the same day. We used placido-scanning-slit topography (ORBscan II), rotating Scheimpflug tomography (Pentacam HR), and swept-source optical coherence tomography (CASIA SS1000). The intraclass correlation coefficients and Bland-Altman plots were used to evaluate the agreement and differences between measurements.

Results: The mean ACD values were 2.88 ± 0.43, 2.82 ± 0.50, and 2.68 ± 0.44 mm; and the mean CCT values were 536.96 ± 31.19, 543.79 ± 31.04, and 561.41 ± 32.60 μm; and the mean keratometry (Km) were 43.81 ± 1.69, 43.81 ± 1.77, and 44.65 ± 1.95 diopters; as measured by CASIA SS-1000, Pentacam HR, and ORBscan II, respectively. Among the three devices, ACD was deepest to shallowest in the order of CASIA SS-1000, Pentacam HR, and ORBscan II (p < 0.05). The CCT was thickest to thinnest in the order of ORBscan II, Pentacam HR, and CASIA SS-1000 (p < 0.05). No significant differences in Km values were examined between CASIA SS-1000 and Pentacam HR, whereas ORBscan II overestimated Km with a statistically significant difference compared to the other two devices.

Conclusions: High level of agreement was found between CASIA SS-1000 and Pentacam HR for anterior parameters, including ACD, CCT, and Km, suggesting interchangeability. However, ORBscan II measurements differed considerably with the measurements obtained from the other two devices; therefore, it should not be used interchangeably. However, further studies with repeatability test should be considered in order to elucidate the reliability of each device.

Citing Articles

Comparison of keratometric values and anterior segment parameters measured using Scheimpflug Sirius topography and Lenstar biometry.

Telek H, Bilen R, Ozdemir Y, Dinc D, Celikay O Int Ophthalmol. 2024; 44(1):103.

PMID: 38376696 DOI: 10.1007/s10792-024-03046-4.


Changes in anterior chamber biometry and intraocular pressure after uneventful phacoemulsification in non-glaucomatous eyes.

Dawood Y, Issa A, Mohammed Ali S Med Hypothesis Discov Innov Ophthalmol. 2023; 12(1):28-35.

PMID: 37641670 PMC: 10445312. DOI: 10.51329/mehdiophthal1467.

References
1.
Wylegala E, Teper S, Nowinska A, Milka M, Dobrowolski D . Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography. J Cataract Refract Surg. 2009; 35(8):1410-4. DOI: 10.1016/j.jcrs.2009.03.034. View

2.
Schroder S, Maurer S, Eppig T, Seitz B, Rubly K, Langenbucher A . Comparison of Corneal Tomography: Repeatability, Precision, Misalignment, Mean Elevation, and Mean Pachymetry. Curr Eye Res. 2018; 43(6):709-716. DOI: 10.1080/02713683.2018.1441873. View

3.
Pardeshi A, Song A, Lazkani N, Xie X, Huang A, Xu B . Intradevice Repeatability and Interdevice Agreement of Ocular Biometric Measurements: A Comparison of Two Swept-Source Anterior Segment OCT Devices. Transl Vis Sci Technol. 2020; 9(9):14. PMC: 7442878. DOI: 10.1167/tvst.9.9.14. View

4.
Angmo D, Singh R, Chaurasia S, Yadav S, Dada T . Evaluation of anterior segment parameters with two anterior segment optical coherence tomography systems: Visante and Casia, in primary angle closure disease. Indian J Ophthalmol. 2019; 67(4):500-504. PMC: 6446640. DOI: 10.4103/ijo.IJO_641_18. View

5.
Yazici A, Bozkurt E, Alagoz C, Alagoz N, Pekel G, Kaya V . Central corneal thickness, anterior chamber depth, and pupil diameter measurements using Visante OCT, Orbscan, and Pentacam. J Refract Surg. 2010; 26(2):127-33. DOI: 10.3928/1081597X-20100121-08. View