Comprehensive Experimental Assessments of Rheological Models' Performance in Elastography of Soft Tissues

Overview
Journal Acta Biomater
Publisher Elsevier
Date 2022 May 7
PMID 35525481
Authors
Affiliations
Soon will be listed here.
Abstract

Elastography researchers have utilized several rheological models to characterize soft tissue viscoelasticity over the past thirty years. Due to the frequency-dependent behavior of viscoelastic parameters as well as the different techniques and frequencies employed in various studies of soft tissues, rheological models have value in standardizing disparate techniques via explicit mathematical representations. However, the important question remains: which of the several available models should be considered for widespread adoption within a theoretical framework? We address this by evaluating the performance of three well established rheological models to characterize ex vivo bovine liver tissues: the Kelvin-Voigt (KV) model as a 2-parameter model, and the standard linear solid (SLS) and Kelvin-Voigt fractional derivative (KVFD) models as 3-parameter models. The assessments were based on the analysis of time domain behavior (using stress relaxation tests) and frequency domain behavior (by measuring shear wave speed (SWS) dispersion). SWS was measured over a wide range of frequency from 1 Hz to 1 kHz using three different tests: (i) harmonic shear tests using a rheometer, (ii) reverberant shear wave (RSW) ultrasound elastography scans, and (iii) RSW optical coherence elastography scans, with each test targeting a distinct frequency range. Our results demonstrated that the KVFD model produces the only mutually consistent rendering of time and frequency domain data for liver. Furthermore, it reduces to a 2-parameter model for liver (correspondingly to a 2-parameter "spring-pot" or power-law model for SWS dispersion) and provides the most accurate predictions of the material viscoelastic behavior in time (>98% accuracy) and frequency (>96% accuracy) domains. STATEMENT OF SIGNIFICANCE: Rheological models are applied in quantifying tissues viscoelastic properties. This study is unique in presenting comprehensive assessments of rheological models.

Citing Articles

Quasi-Static Mechanical Biomimetics Evaluation of Car Crash Dummy Skin.

Li Y, Liu Z, Sun C, Zheng X, Du G, Wang X Biomimetics (Basel). 2024; 9(12).

PMID: 39727766 PMC: 11673420. DOI: 10.3390/biomimetics9120762.


Mathematical Models for Ultrasound Elastography: Recent Advances to Improve Accuracy and Clinical Utility.

Farajpour A, Ingman W Bioengineering (Basel). 2024; 11(10).

PMID: 39451367 PMC: 11504237. DOI: 10.3390/bioengineering11100991.


A Comprehensive Review on the Viscoelastic Parameters Used for Engineering Materials, Including Soft Materials, and the Relationships between Different Damping Parameters.

Koruk H, Rajagopal S Sensors (Basel). 2024; 24(18).

PMID: 39338881 PMC: 11435754. DOI: 10.3390/s24186137.


Mechanical rheological model on the assessment of elasticity and viscosity in tissue inflammation: A systematic review.

Kimondo J, Said R, Wu J, Tian C, Wu Z PLoS One. 2024; 19(7):e0307113.

PMID: 39008477 PMC: 11249233. DOI: 10.1371/journal.pone.0307113.


Viscoelastic Characterization of Phantoms for Ultrasound Elastography Created Using Low- and High-Viscosity Poly(vinyl alcohol) with Ethylene Glycol as the Cryoprotectant.

Bisht S, Marri B, Karmakar J, Mercado Shekhar K ACS Omega. 2024; 9(7):8352-8361.

PMID: 38405437 PMC: 10882697. DOI: 10.1021/acsomega.3c09224.


References
1.
Tzschatzsch H, Ipek-Ugay S, Nguyen Trong M, Guo J, Eggers J, Gentz E . Multifrequency time-harmonic elastography for the measurement of liver viscoelasticity in large tissue windows. Ultrasound Med Biol. 2015; 41(3):724-33. DOI: 10.1016/j.ultrasmedbio.2014.11.009. View

2.
Parker K . A microchannel flow model for soft tissue elasticity. Phys Med Biol. 2014; 59(15):4443-57. DOI: 10.1088/0031-9155/59/15/4443. View

3.
Amador C, Urban M, Chen S, Greenleaf J . Shearwave dispersion ultrasound vibrometry (SDUV) on swine kidney. IEEE Trans Ultrason Ferroelectr Freq Control. 2013; 58(12):2608-19. PMC: 3588601. DOI: 10.1109/TUFFC.2011.2124. View

4.
Gomez A, Rus G, Saffari N . Wave Propagation in a Fractional Viscoelastic Tissue Model: Application to Transluminal Procedures. Sensors (Basel). 2021; 21(8). PMC: 8071186. DOI: 10.3390/s21082778. View

5.
Caputo M, Carcione J, Cavallini F . Wave simulation in biologic media based on the Kelvin-Voigt fractional-derivative stress-strain relation. Ultrasound Med Biol. 2011; 37(6):996-1004. DOI: 10.1016/j.ultrasmedbio.2011.03.009. View