» Articles » PMID: 35496962

A Pilot Study to Determine the Utility of Automated Tissue Dissociator for Flowcytometry Based Evaluation of Hematolymphoid Tumor Tissue Biopsies

Abstract

Routine diagnostic biopsy tissue processing, conventional histology/immunohistochemistry (IHC) method is a multi-step and time consuming practice. With the advanced tissue dissociation protocols and panel designing, flow cytometric immunophenotyping (FCI) can be performed on diagnostic hematolymphoid tissue samples using single cell suspensions that economize steps and the time taken. Diagnostic tissue samples from lymph node, mediastinal mass, testicular biopsies and similar sites were dissociated using gentle MACS Octo-dissociator and FCI was performed thereafter. Oral tissue biopsy samples were also processed as a validation set for the protocol. 21 prospective tissue biopsy samples with suspected involvement by a known hematolymphoid neoplasm were processed and evaluated. These included B lymphoblastic lymphoma (n = 12), T lymphoblastic lymphomas (n = 3), Burkitts lymphoma (n = 3) and one case each of granulocytic sarcoma, Hodgkin lymphoma and granulomatous disease. Tissue FCI and IHC were found concordant with identified profile FCI obtained from blood/bone marrow analyses. FCI can produce a highly sensitive and reliable report, within hours, by processing fresh tumor tissue samples from suspected hematolymphoid malignancies. This method can be considered as an effective adjunct to IHC and can be applicable in routine clinical diagnostics, especially in cases that needs quick diagnosis and immediate clinical treatment.

Citing Articles

Using mass cytometry for the analysis of samples of the human airways.

Rocha-Hasler M, Muller L, Wagner A, Tu A, Stanek V, Campion N Front Immunol. 2022; 13:1004583.

PMID: 36578479 PMC: 9791368. DOI: 10.3389/fimmu.2022.1004583.

References
1.
Boyd J, Smith G, Hong H, Mageau R, Juskevicius R . Fine-needle aspiration is superior to needle core biopsy as a sample acquisition method for flow cytometric analysis in suspected hematologic neoplasms. Cytometry B Clin Cytom. 2014; 88(1):64-8. DOI: 10.1002/cyto.b.21183. View

2.
Barroca H, Marques C . A Basic Approach to Lymph Node and Flow Cytometry Fine-Needle Cytology. Acta Cytol. 2016; 60(4):284-301. DOI: 10.1159/000448679. View

3.
Scott G, Atwater S, Gratzinger D . Normative data for flow cytometry immunophenotyping of benign lymph nodes sampled by surgical biopsy. J Clin Pathol. 2017; 71(2):174-179. PMC: 5800326. DOI: 10.1136/jclinpath-2017-204687. View

4.
Reichard A, Asosingh K . Best Practices for Preparing a Single Cell Suspension from Solid Tissues for Flow Cytometry. Cytometry A. 2018; 95(2):219-226. PMC: 6375754. DOI: 10.1002/cyto.a.23690. View

5.
Leelatian N, Doxie D, Greenplate A, Sinnaeve J, Ihrie R, Irish J . Preparing Viable Single Cells from Human Tissue and Tumors for Cytomic Analysis. Curr Protoc Mol Biol. 2017; 118:25C.1.1-25C.1.23. PMC: 5518778. DOI: 10.1002/cpmb.37. View