» Articles » PMID: 35436870

Comparison of Different Pupil Dilatation Methods for Phacoemulsification in Eyes with a Small Pupil

Overview
Journal BMC Ophthalmol
Publisher Biomed Central
Specialty Ophthalmology
Date 2022 Apr 19
PMID 35436870
Authors
Affiliations
Soon will be listed here.
Abstract

Purpose: To compare 6 methods for intraoperative pupil dilatation in eyes with insufficient pupil size during phacoemulsification.

Methods: This was a prospective case-control study. 99 microcoria cataract patients (120 eyes) were collected and were divided into 6 groups(20 eyes each group), and their pupils were dilated by bimanual stretching pupil (group I), pupil radial cut open(group II), mechanical pupil dilatation with iris-retractor hooks (group III), OASIS iris expander (group IV), and Malyguin-ring (Microsurgical company, America) (group V), B-HEX Pupil Expander (Med Invent Devics, India)(group VI),respectively. 3.0 mm clear corneal incision were used in phacoemulsification. All cases were followed up at 1 week and 1, 3, 6 months after the surgery. The best corrected visual acuity (BCVA), intraocular pressure(IOP), corneal endothelium cell density(ECD), pupil diameter(PD) of before and after surgery were compared.

Results: One same doctor finished all cataract surgeries successfully. The eyes' condition before surgery and at 6 months after surgery were compared. There were no significant statistical differences for the conditions of the eyes before surgery among six groups. The ECDs were better at 6 months postoperatively in group III and V, median values: 2114/mm, 1961/mm. PD was largest in group II (median value: 5.5 mm), which was significantly larger than other groups (P < 0.05).

Conclusions: All 6 methods used in this study were effective for the mechanical dilatation of small pupils and didn't affect the postoperative visual acuity and intraocular pressure in microcoria cataract phacoemulsification. Iris-retractor hooks and the Malyugin Ring can reduce intraoperative corneal endothelium cell loss. Postoperative PD is larger when the iris was cut open radially.

Citing Articles

Exploring the impact of pupil expansion techniques on cataract surgery: unveiling key complications and clinical outcomes: a comparative analysis of 1266 eyes.

Achiron A, Yahalomi T, Ostrovsky M, Levinger E, Cohen E, Elhaddad O Graefes Arch Clin Exp Ophthalmol. 2025; .

PMID: 39900804 DOI: 10.1007/s00417-025-06748-2.


Eight-Chop Technique in Phacoemulsification Using Iris Hooks for Patients with Cataracts and Small Pupils.

Sato T J Clin Med. 2024; 13(23).

PMID: 39685756 PMC: 11641855. DOI: 10.3390/jcm13237298.


Bimanual technique for placement of footplates of phakic intraocular lens in eyes with intraoperative miosis.

Sinha R, Anjum S, Bari A Indian J Ophthalmol. 2024; 72(9):1352-1354.

PMID: 38634771 PMC: 11552813. DOI: 10.4103/IJO.IJO_3003_23.


Comparison of pupil expansion devices in small pupil phacoemulsification.

Potti S, Reddy Sodum N Indian J Ophthalmol. 2024; 72(Suppl 4):S664-S668.

PMID: 38389262 PMC: 11338422. DOI: 10.4103/IJO.IJO_1420_23.


A new intraocular lens marker to guide the implantation of toric intraocular lenses in small and mid-dilating pupils.

Ganesh S, Brar S, Chakma A Indian J Ophthalmol. 2023; 71(5):2251-2253.

PMID: 37202962 PMC: 10391429. DOI: 10.4103/ijo.IJO_1979_22.


References
1.
Wang J, Zhang J, Xiong Y, Li J, Li X, Liu X . Congenital aniridia with cataract: case series. BMC Ophthalmol. 2017; 17(1):115. PMC: 5496261. DOI: 10.1186/s12886-017-0503-6. View

2.
Musat O, Mahdi L, Gheorghe A, Burcea M, Cernat C, Cristescu R . [Malyugin ring--an alternative in the treatment of a miotic pupil]. Oftalmologia. 2014; 58(2):40-2. View

3.
Bhattacharjee S . B-HEX pupil expander: Pupil expansion redefined. Indian J Ophthalmol. 2017; 65(12):1407-1410. PMC: 5742970. DOI: 10.4103/ijo.IJO_673_17. View

4.
Auffarth G, Reuland A, Heger T, Volcker H . Cataract surgery in eyes with iridoschisis using the Perfect Pupil iris extension system. J Cataract Refract Surg. 2005; 31(10):1877-80. DOI: 10.1016/j.jcrs.2005.03.070. View

5.
Wilczynski M, Wierzchowski T, Synder A, Omulecki W . Results of phacoemulsification with Malyugin Ring in comparison with manual iris stretching with hooks in eyes with narrow pupil. Eur J Ophthalmol. 2012; 23(2):196-201. DOI: 10.5301/ejo.5000204. View