Background: Ultrasound evaluation of inferior vena cava and internal jugular vein dia-meters predicts the intravascular volume status in critical patients. The aim of the present study was to determine which ultrasound-derived index is most strongly associated with central venous pressure (CVP). Furthermore, we determined the utility of selected variables in predicting low volume status (CVP < 8 mmHg).
Methods: All patients underwent a transthoracic echocardiogram, vascular ultrasound examination, invasive central venous pressure, and intra-abdominal pressure determination. The following indexes were calculated: inferior vena cava diameter, internal jugular vein maximum diameter, collapsibility index, and internal jugular vein ratio.
Results: 41 spontaneously breathing patients were recruited. Central venous pressure significantly correlated with inferior vena cava diameter ( r = 0.35, P = 0.02), internal jugular vein ratio ( r = 0.35, P = 0.03), and internal jugular vein maximum diameter ( r = 0.58, P < 0.001). The inferior vena cava collapsibility index did not show any association. The areas under the receiver operating characteristic curves to discriminate a low central venous pressure (< 8 mmHg) were the following: internal jugular vein diameter 0.80 (95% CI: 0.63-0.90); inferior vena cava diameter 0.66 (95% CI: 0.49-0.80); and internal jugular vein ratio 0.68 (95% CI: 0.51-0.82).
Conclusions: The internal jugular vein diameter, the internal jugular vein ratio, and the inferior vena cava diameter showed a significant correlation with central venous pressure. In particular, the internal jugular vein diameter showed good accuracy in predicting a low central venous pressure.
Yu Q, Dai S, Chen X, Zhang X, Chen X Am J Transl Res. 2024; 16(10):5981-5989.
PMID: 39544761 PMC: 11558391. DOI: 10.62347/QMYL9341.
Dojcinovic B, Banjac N, Vukmirovic S, Dojcinovic T, Vasovic L, Mihajlovic D Medicina (Kaunas). 2024; 60(9).
PMID: 39336562 PMC: 11433694. DOI: 10.3390/medicina60091521.
Ultrasound based estimate of central venous pressure: Are we any closer?.
Gawalkar A, Batta A World J Cardiol. 2024; 16(6):310-313.
PMID: 38993581 PMC: 11235208. DOI: 10.4330/wjc.v16.i6.310.
Chayapinun V, Koratala A, Assavapokee T World J Cardiol. 2024; 16(2):73-79.
PMID: 38456073 PMC: 10915892. DOI: 10.4330/wjc.v16.i2.73.