» Articles » PMID: 35414986

First-in-clinical Application of a Time-gated Diffuse Correlation Spectroscopy System at 1064 nm Using Superconducting Nanowire Single Photon Detectors in a Neuro Intensive Care Unit

Overview
Specialty Radiology
Date 2022 Apr 13
PMID 35414986
Authors
Affiliations
Soon will be listed here.
Abstract

Recently proposed time-gated diffuse correlation spectroscopy (TG-DCS) has significant advantages compared to conventional continuous wave (CW)-DCS, but it is still in an early stage and clinical capability has yet to be established. The main challenge for TG-DCS is the lower signal-to-noise ratio (SNR) when gating for the deeper traveling late photons. Longer wavelengths, such as 1064 nm have a smaller effective attenuation coefficient and a higher power threshold in humans, which significantly increases the SNR. Here, we demonstrate the clinical utility of TG-DCS at 1064 nm in a case study on a patient with severe traumatic brain injury admitted to the neuro-intensive care unit (neuroICU). We showed a significant correlation between TG-DCS early (ρ = 0.67) and late (ρ = 0.76) gated against invasive thermal diffusion flowmetry. We also analyzed TG-DCS at high temporal resolution (50 Hz) to elucidate pulsatile flow data. Overall, this study demonstrates the first clinical translation capability of the TG-DCS system at 1064 nm using a superconducting nanowire single-photon detector.

Citing Articles

Time-domain diffuse correlation spectroscopy at large source detector separation for cerebral blood flow recovery.

Mogharari N, Wojtkiewicz S, Borycki D, Liebert A, Kacprzak M Biomed Opt Express. 2024; 15(7):4330-4344.

PMID: 39022555 PMC: 11249683. DOI: 10.1364/BOE.523514.


Introduction to the Optics and the Brain 2023 feature issue.

Bauer A, Gibson E, Wang H, Srinivasan V Biomed Opt Express. 2024; 15(4):2110-2113.

PMID: 38633102 PMC: 11019680. DOI: 10.1364/BOE.517678.


Interferometric near-infrared spectroscopy (iNIRS) reveals that blood flow index depends on wavelength.

Mazumder D, Kholiqov O, Srinivasan V Biomed Opt Express. 2024; 15(4):2152-2174.

PMID: 38633063 PMC: 11019706. DOI: 10.1364/BOE.507373.


Validation of the Openwater wearable optical system: cerebral hemodynamic monitoring during a breath-hold maneuver.

Favilla C, Carter S, Hartl B, Gitlevich R, Mullen M, Yodh A Neurophotonics. 2024; 11(1):015008.

PMID: 38464864 PMC: 10923543. DOI: 10.1117/1.NPh.11.1.015008.


Comparing the performance potential of speckle contrast optical spectroscopy and diffuse correlation spectroscopy for cerebral blood flow monitoring using Monte Carlo simulations in realistic head geometries.

Robinson M, Cheng T, Renna M, Wu M, Kim B, Cheng X Neurophotonics. 2024; 11(1):015004.

PMID: 38282721 PMC: 10821780. DOI: 10.1117/1.NPh.11.1.015004.


References
1.
Pagliazzi M, Colombo L, Vidal-Rosas E, Dragojevic T, Parfentyeva V, Culver J . Time resolved speckle contrast optical spectroscopy at quasi-null source-detector separation for non-invasive measurement of microvascular blood flow. Biomed Opt Express. 2021; 12(3):1499-1511. PMC: 7984782. DOI: 10.1364/BOE.418882. View

2.
Samaei S, Sawosz P, Kacprzak M, Pastuszak Z, Borycki D, Liebert A . Time-domain diffuse correlation spectroscopy (TD-DCS) for noninvasive, depth-dependent blood flow quantification in human tissue in vivo. Sci Rep. 2021; 11(1):1817. PMC: 7815740. DOI: 10.1038/s41598-021-81448-5. View

3.
Colombo L, Pagliazzi M, Konugolu Venkata Sekar S, Contini D, Dalla Mora A, Spinelli L . Effects of the instrument response function and the gate width in time-domain diffuse correlation spectroscopy: model and validations. Neurophotonics. 2019; 6(3):035001. PMC: 6624407. DOI: 10.1117/1.NPh.6.3.035001. View

4.
Foreman B, Claassen J . Quantitative EEG for the detection of brain ischemia. Crit Care. 2012; 16(2):216. PMC: 3681361. DOI: 10.1186/cc11230. View

5.
Li J, Qiu L, Poon C, Sunar U . Analytical models for time-domain diffuse correlation spectroscopy for multi-layer and heterogeneous turbid media. Biomed Opt Express. 2018; 8(12):5518-5532. PMC: 5745100. DOI: 10.1364/BOE.8.005518. View