Comparison of Signal Processing Methods for Reducing Motion Artifacts in High-Density Electromyography During Human Locomotion

Overview
Publisher IEEE
Date 2022 Apr 11
PMID 35402949
Authors
Affiliations
Soon will be listed here.
Abstract

High-density electromyography (EMG) is useful for studying changes in myoelectric activity within a muscle during human movement, but it is prone to motion artifacts during locomotion. We compared canonical correlation analysis and principal component analysis methods for signal decomposition and component filtering with a traditional EMG high-pass filtering approach to quantify their relative performance at removing motion artifacts from high-density EMG of the gastrocnemius and tibialis anterior muscles during human walking and running. Canonical correlation analysis filtering provided a greater reduction in signal content at frequency bands associated with motion artifacts than either traditional high-pass filtering or principal component analysis filtering. Canonical correlation analysis filtering also minimized signal reduction at frequency bands expected to consist of true myoelectric signal. Canonical correlation analysis filtering appears to outperform a standard high-pass filter and principal component analysis filter in cleaning high-density EMG collected during fast walking or running.

Citing Articles

Improved multi-layer wavelet transform and blind source separation based ECG artifacts removal algorithm from the sEMG signal: in the case of upper limbs.

Lu W, Gong D, Xue X, Gao L Front Bioeng Biotechnol. 2024; 12:1367929.

PMID: 38832128 PMC: 11145508. DOI: 10.3389/fbioe.2024.1367929.


Quantifying the Suitability of Biosignals Acquired During Surgery for Multimodal Analysis.

Idrobo-Avila E, Bognar G, Krefting D, Penzel T, Kovacs P, Spicher N IEEE Open J Eng Med Biol. 2024; 5:250-260.

PMID: 38766543 PMC: 11100950. DOI: 10.1109/OJEMB.2024.3379733.


Signal Quality Analysis of Single-Arm Electrocardiography.

Wang J, Liu S, Tsai C, Manousakas I, Zhu X, Lee T Sensors (Basel). 2023; 23(13).

PMID: 37447668 PMC: 10346735. DOI: 10.3390/s23135818.


Using Ballistocardiogram and Impedance Plethysmogram for Minimal Contact Measurement of Blood Pressure Based on a Body Weight-Fat Scale.

Liu S, Wu Y, Chen W, Su C, Chin C Sensors (Basel). 2023; 23(4).

PMID: 36850917 PMC: 9966183. DOI: 10.3390/s23042318.


Customizable, reconfigurable, and anatomically coordinated large-area, high-density electromyography from drawn-on-skin electrode arrays.

Ershad F, Houston M, Patel S, Contreras L, Koirala B, Lu Y PNAS Nexus. 2023; 2(1):pgac291.

PMID: 36712933 PMC: 9837666. DOI: 10.1093/pnasnexus/pgac291.


References
1.
Sacco I, Hamamoto A, Onodera A, A Gomes A, Weiderpass H, Pachi C . Motor strategy patterns study of diabetic neuropathic individuals while walking. A wavelet approach. J Biomech. 2014; 47(10):2475-82. DOI: 10.1016/j.jbiomech.2014.04.007. View

2.
Keenan K, Collins J, Massey W, Walters T, Gruszka H . Coherence between surface electromyograms is influenced by electrode placement in hand muscles. J Neurosci Methods. 2010; 195(1):10-4. DOI: 10.1016/j.jneumeth.2010.10.018. View

3.
Vieira T, Loram I, Muceli S, Merletti R, Farina D . Postural activation of the human medial gastrocnemius muscle: are the muscle units spatially localised?. J Physiol. 2010; 589(Pt 2):431-43. PMC: 3043543. DOI: 10.1113/jphysiol.2010.201806. View

4.
Clancy E, Morin E, Merletti R . Sampling, noise-reduction and amplitude estimation issues in surface electromyography. J Electromyogr Kinesiol. 2002; 12(1):1-16. DOI: 10.1016/s1050-6411(01)00033-5. View

5.
Wakeling J, Pascual S, Nigg B, Von Tscharner V . Surface EMG shows distinct populations of muscle activity when measured during sustained sub-maximal exercise. Eur J Appl Physiol. 2002; 86(1):40-7. DOI: 10.1007/s004210100508. View