Can Seismocardiogram Fiducial Points Be Used for the Routine Estimation of Cardiac Time Intervals in Cardiac Patients?

Overview
Journal Front Physiol
Date 2022 Apr 11
PMID 35399285
Authors
Affiliations
Soon will be listed here.
Abstract

The indexes of cardiac mechanics can be derived from the cardiac time intervals, CTIs, i.e., the timings among the opening and closure of the aortic and mitral valves and the Q wave in the ECG. Traditionally, CTIs are estimated by ultrasound (US) techniques, but they may also be more easily assessed by the identification of specific fiducial points (FPs) inside the waveform of the seismocardiogram (SCG), i.e., the measure of the thorax micro-accelerations produced by the heart motion. While the correspondence of the FPs with the valve movements has been verified in healthy subjects, less information is available on whether this methodology may be routinely employed in the clinical practice for the monitoring of cardiac patients, in which an SCG waveform distortion is expected because of the heart dysfunction. In this study we checked the SCG shape in 90 patients with myocardial infarction (MI), heart failure (HF), or transplanted heart (TX), referred to our hospital for rehabilitation after an acute event or after surgery. The SCG shapes were classified as traditional (T) or non-traditional (NT) on whether the FPs were visible or not on the basis of nomenclature previously proposed in literature. The T shape was present in 62% of the patients, with a higher ∓ prevalence in MI (79%). No relationship was found between T prevalence and ejection fraction (EF). In 20 patients with T shape, we checked the FPs correspondence with the real valve movements by concomitant SCG and US measures. When compared with reference values in healthy subjects available in the literature, we observed that the Echo vs. FP differences are significantly more dispersed in the patients than in the healthy population with higher differences for the estimation of the mitral valve closure (-17 vs. 4 ms on average). Our results indicate that not every cardiac patient has an SCG waveform suitable for the CTI estimation, thus before starting an SCG-based CTI monitoring a preliminary check by a simultaneous SCG-US measure is advisable to verify the applicability of the methodology.

Citing Articles

Fully automated template matching method for ECG-free heartbeat detection in cardiomechanical signals of healthy and pathological subjects.

Parlato S, Centracchio J, Esposito D, Bifulco P, Andreozzi E Phys Eng Sci Med. 2025; .

PMID: 40080259 DOI: 10.1007/s13246-025-01531-3.


On the design and development of a handheld electrocardiogram device in a clinical setting.

Zepeda-Echavarria A, Ratering Arntz N, Westra A, van Schelven L, Euwe F, Noordmans H Front Digit Health. 2024; 6:1403457.

PMID: 39184339 PMC: 11341539. DOI: 10.3389/fdgth.2024.1403457.


ECG-Free Heartbeat Detection in Seismocardiography and Gyrocardiography Signals Provides Acceptable Heart Rate Variability Indices in Healthy and Pathological Subjects.

Parlato S, Centracchio J, Esposito D, Bifulco P, Andreozzi E Sensors (Basel). 2023; 23(19).

PMID: 37836942 PMC: 10575135. DOI: 10.3390/s23198114.


Heartbeat Detection in Gyrocardiography Signals without Concurrent ECG Tracings.

Parlato S, Centracchio J, Esposito D, Bifulco P, Andreozzi E Sensors (Basel). 2023; 23(13).

PMID: 37448046 PMC: 10347297. DOI: 10.3390/s23136200.


ECG-Free Heartbeat Detection in Seismocardiography Signals via Template Matching.

Centracchio J, Parlato S, Esposito D, Bifulco P, Andreozzi E Sensors (Basel). 2023; 23(10).

PMID: 37430606 PMC: 10224046. DOI: 10.3390/s23104684.


References
1.
Wahlstrom J, Skog I, Handel P, Khosrow-Khavar F, Tavakolian K, Stein P . A Hidden Markov Model for Seismocardiography. IEEE Trans Biomed Eng. 2017; 64(10):2361-2372. DOI: 10.1109/TBME.2017.2648741. View

2.
Liu H, Allen J, Zheng D, Chen F . Recent development of respiratory rate measurement technologies. Physiol Meas. 2019; 40(7):07TR01. DOI: 10.1088/1361-6579/ab299e. View

3.
MOUNSEY P . Praecordial ballistocardiography. Br Heart J. 1957; 19(2):259-71. PMC: 479624. DOI: 10.1136/hrt.19.2.259. View

4.
Myreng Y, Smiseth O . Assessment of left ventricular relaxation by Doppler echocardiography. Comparison of isovolumic relaxation time and transmitral flow velocities with time constant of isovolumic relaxation. Circulation. 1990; 81(1):260-6. DOI: 10.1161/01.cir.81.1.260. View

5.
Shokouhmand A, Aranoff N, Driggin E, Green P, Tavassolian N . Efficient detection of aortic stenosis using morphological characteristics of cardiomechanical signals and heart rate variability parameters. Sci Rep. 2021; 11(1):23817. PMC: 8664843. DOI: 10.1038/s41598-021-03441-2. View