» Articles » PMID: 35372920

Buttonhole Cannulation of Arteriovenous Fistulas in the United States

Overview
Journal Kidney360
Specialty Nephrology
Date 2022 Apr 4
PMID 35372920
Authors
Affiliations
Soon will be listed here.
Abstract

The cannulation technique of a hemodialysis vascular access has remained controversial with differing viewpoints. The quality of dialysis, overall patient safety, and individual dialysis experience often dictate the type of cannulation technique used in clinical practice. The three commonly used techniques to access a hemodialysis vascular access are the rope ladder, area, and buttonhole. Although the buttonhole technique has been around since the mid-1970s, the dialysis community remains divided on its suitability for routine use to provide maintenance hemodialysis therapy. The proponents of this technique value the ease of cannulation with less pain and discomfort whereas the opponents highlight the increased risk of infection. The actual clinical evidence from the United States is limited and remains inconclusive. The current review provides an overview of the available experience from the United States, highlighting the correct technique of creating a buttonhole, summarizing the current evidence, and recommending a need for larger randomized controlled studies in both in-center and home hemodialysis populations.

Citing Articles

Research on comprehensive analysis of patient comfort and complication rate using haemodialysis indwelling needles in AVF puncture in haemodialysis treatment.

Jin G, Gu J, Zhang Y, Ren S Eur J Transl Myol. 2024; 34(2).

PMID: 38687343 PMC: 11264225. DOI: 10.4081/ejtm.2024.12422.


The development of the Western Australian Haemodialysis Vascular Access Complexity instrument.

Coventry L, Hosking J, Coral E, Jenkins M, Salgado Kent C, Chan D J Ren Care. 2021; 48(3):185-196.

PMID: 34181822 PMC: 9543205. DOI: 10.1111/jorc.12390.

References
1.
Ball L . The buttonhole technique: strategies to reduce infections. Nephrol Nurs J. 2010; 37(5):473-7. View

2.
Ball L, Treat L, Riffle V, Scherting D, Swift L . A multi-center perspective of the Buttonhole Technique in the Pacific Northwest. Nephrol Nurs J. 2007; 34(2):234-41. View

3.
MacRae J, Ahmed S, Atkar R, Hemmelgarn B . A randomized trial comparing buttonhole with rope ladder needling in conventional hemodialysis patients. Clin J Am Soc Nephrol. 2012; 7(10):1632-8. PMC: 3463206. DOI: 10.2215/CJN.02730312. View

4.
Toma S, Shinzato T, Fukui H, Nakai S, Miwa M, Takai I . A timesaving method to create a fixed puncture route for the buttonhole technique. Nephrol Dial Transplant. 2003; 18(10):2118-21. DOI: 10.1093/ndt/gfg321. View

5.
Nesrallah G, Cuerden M, Wong J, Pierratos A . Staphylococcus aureus bacteremia and buttonhole cannulation: long-term safety and efficacy of mupirocin prophylaxis. Clin J Am Soc Nephrol. 2010; 5(6):1047-53. PMC: 2879300. DOI: 10.2215/CJN.00280110. View