» Articles » PMID: 35356509

Wearable Photoplethysmography for Cardiovascular Monitoring

Overview
Authors
Affiliations
Soon will be listed here.
Abstract

Smart wearables provide an opportunity to monitor health in daily life and are emerging as potential tools for detecting cardiovascular disease (CVD). Wearables such as fitness bands and smartwatches routinely monitor the photoplethysmogram signal, an optical measure of the arterial pulse wave that is strongly influenced by the heart and blood vessels. In this survey, we summarize the fundamentals of wearable photoplethysmography and its analysis, identify its potential clinical applications, and outline pressing directions for future research in order to realize its full potential for tackling CVD.

Citing Articles

The Role of AI in Cardiovascular Event Monitoring and Early Detection: Scoping Literature Review.

Elvas L, Almeida A, Ferreira J JMIR Med Inform. 2025; 13:e64349.

PMID: 40048151 PMC: 11905924. DOI: 10.2196/64349.


The MSPTDfast photoplethysmography beat detection algorithm: design, benchmarking, and open-source distribution.

Charlton P, Arguello Prada E, Arguello-Prada E, Mant J, Kyriacou P, Kyriacou P Physiol Meas. 2025; 46(3).

PMID: 39978069 PMC: 11894679. DOI: 10.1088/1361-6579/adb89e.


An ideally designed deep trust network model for heart disease prediction based on seagull optimization and Ruzzo Tompa algorithm.

Jin Y, Lai Y, Hoshyar A, Innab N, Shutaywi M, Deebani W Sci Rep. 2025; 15(1):6035.

PMID: 39971944 PMC: 11839990. DOI: 10.1038/s41598-025-89348-8.


Wearables in Chronomedicine and Interpretation of Circadian Health.

Gubin D, Weinert D, Stefani O, Otsuka K, Borisenkov M, Cornelissen G Diagnostics (Basel). 2025; 15(3).

PMID: 39941257 PMC: 11816745. DOI: 10.3390/diagnostics15030327.


Exploring Near- and Far-Field Effects in Photoplethysmography Signals Across Different Source-Detector Distances.

Sole Morillo A, Cause J, De Pauw K, Silva B, Stiens J Sensors (Basel). 2025; 25(1.

PMID: 39796889 PMC: 11722670. DOI: 10.3390/s25010099.


References
1.
Kamboj N, Chang K, Metcalfe K, Chu C, Conway A . Accuracy and precision of continuous non-invasive arterial pressure monitoring in critical care: A systematic review and meta-analysis. Intensive Crit Care Nurs. 2021; 67:103091. DOI: 10.1016/j.iccn.2021.103091. View

2.
Mateo J, Laguna P . Analysis of heart rate variability in the presence of ectopic beats using the heart timing signal. IEEE Trans Biomed Eng. 2003; 50(3):334-43. DOI: 10.1109/TBME.2003.808831. View

3.
Seshadri D, Davies E, Harlow E, Hsu J, Knighton S, Walker T . Wearable Sensors for COVID-19: A Call to Action to Harness Our Digital Infrastructure for Remote Patient Monitoring and Virtual Assessments. Front Digit Health. 2021; 2:8. PMC: 8521919. DOI: 10.3389/fdgth.2020.00008. View

4.
Mol B, Roberts C, Thangaratinam S, Magee L, de Groot C, Hofmeyr G . Pre-eclampsia. Lancet. 2015; 387(10022):999-1011. DOI: 10.1016/S0140-6736(15)00070-7. View

5.
Ebmeier S, Barker M, Bacon M, Beasley R, Bellomo R, Knee Chong C . A two centre observational study of simultaneous pulse oximetry and arterial oxygen saturation recordings in intensive care unit patients. Anaesth Intensive Care. 2018; 46(3):297-303. DOI: 10.1177/0310057X1804600307. View