» Articles » PMID: 35336408

A Comprehensive Review of Metal-Organic Framework: Synthesis, Characterization, and Investigation of Their Application in Electrochemical Biosensors for Biomedical Analysis

Overview
Journal Sensors (Basel)
Publisher MDPI
Specialty Biotechnology
Date 2022 Mar 26
PMID 35336408
Authors
Affiliations
Soon will be listed here.
Abstract

Many studies have addressed electrochemical biosensors because of their simple synthesis process, adjustability, simplification, manipulation of materials' compositions and features, and wide ranges of detection of different kinds of biomedical analytes. Performant electrochemical biosensors can be achieved by selecting materials that enable faster electron transfer, larger surface areas, very good electrocatalytic activities, and numerous sites for bioconjugation. Several studies have been conducted on the metal-organic frameworks (MOFs) as electrode modifiers for electrochemical biosensing applications because of their respective acceptable properties and effectiveness. Nonetheless, researchers face challenges in designing and preparing MOFs that exhibit higher stability, sensitivity, and selectivity to detect biomedical analytes. The present review explains the synthesis and description of MOFs, and their relative uses as biosensors in the healthcare sector by dealing with the biosensors for drugs, biomolecules, as well as biomarkers with smaller molecular weight, proteins, and infectious disease.

Citing Articles

Emerging trends in functional materials for electrochemical sensors in nicotine determination.

Zheng A, Teo E, Yiu P, Boonyuen S, Andou Y Anal Sci. 2024; 40(11):1933-1946.

PMID: 39030465 DOI: 10.1007/s44211-024-00629-0.


Not Only Graphene Two-Dimensional Nanomaterials: Recent Trends in Electrochemical (Bio)sensing Area for Biomedical and Healthcare Applications.

Di Matteo P, Petrucci R, Curulli A Molecules. 2024; 29(1).

PMID: 38202755 PMC: 10780376. DOI: 10.3390/molecules29010172.


PCL/PEO Polymer Membrane Prevents Biofouling in Wearable Detection Sensors.

Delgado-Rivera R, Garcia-Rodriguez W, Lopez L, Cunci L, Resto P, Domenech M Membranes (Basel). 2023; 13(8).

PMID: 37623789 PMC: 10456225. DOI: 10.3390/membranes13080728.


Recent Developments on the Catalytic and Biosensing Applications of Porous Nanomaterials.

Pal N, Chakraborty D, Cho E, Gil Seo J Nanomaterials (Basel). 2023; 13(15).

PMID: 37570502 PMC: 10420944. DOI: 10.3390/nano13152184.


Methanol and Ethanol Electrooxidation on ZrO/NiO/rGO.

Askari M, Beitollahi H, Di Bartolomeo A Nanomaterials (Basel). 2023; 13(4).

PMID: 36839047 PMC: 9964513. DOI: 10.3390/nano13040679.


References
1.
Fujii K, Lazuen Garay A, Hill J, Sbircea E, Pan Z, Xu M . Direct structure elucidation by powder X-ray diffraction of a metal-organic framework material prepared by solvent-free grinding. Chem Commun (Camb). 2010; 46(40):7572-4. DOI: 10.1039/c0cc02635b. View

2.
Dai G, Li Z, Luo F, Lu Y, Chu Z, Zhang J . Simultaneous electrochemical determination of nuc and mecA genes for identification of methicillin-resistant Staphylococcus aureus using N-doped porous carbon and DNA-modified MOF. Mikrochim Acta. 2021; 188(2):39. DOI: 10.1007/s00604-020-04698-6. View

3.
Hatami Z, Jalali F, Amouzadeh Tabrizi M, Shamsipur M . Application of metal-organic framework as redox probe in an electrochemical aptasensor for sensitive detection of MUC1. Biosens Bioelectron. 2019; 141:111433. DOI: 10.1016/j.bios.2019.111433. View

4.
Rocha-Gaso M, March-Iborra C, Montoya-Baides A, Arnau-Vives A . Surface generated acoustic wave biosensors for the detection of pathogens: a review. Sensors (Basel). 2012; 9(7):5740-69. PMC: 3274150. DOI: 10.3390/s90705740. View

5.
Wei J, Gong F, Sun X, Li Y, Zhang T, Zhao X . Rapid and Low-Cost Electrochemical Synthesis of UiO-66-NH with Enhanced Fluorescence Detection Performance. Inorg Chem. 2019; 58(10):6742-6747. DOI: 10.1021/acs.inorgchem.9b00157. View